用于荧光测定甲硝唑的非共轭聚合物碳点。

Non-conjugated polymer carbon dots for fluorometric determination of metronidazole.

机构信息

College of Chemistry, Jilin University, Changchun, 130012, China.

Shenyang Academy of Environmental Sciences, Liaoning Provincial Key Laboratory for Urban Ecology, Shenyang, 110167, China.

出版信息

Mikrochim Acta. 2019 Aug 28;186(9):652. doi: 10.1007/s00604-019-3746-5.

Abstract

Non-conjugated polymer carbon dots (PCDs) with a 9% fluorescence quantum yield were synthesized by a pyrolytic method using polyethyleneimine as the sole precursor. The PCDs have an average size about 2.1 nm and a blue fluorescence, with excitation/emission maxima at 380/457 nm, that is quenched by the drug metronidazole. The method has a linear response in the 0.06-15 μg mL metronidazole concentration range and a 20 ng mL detection limit. Milk samples were spiked at two levels (0.6 and 5.0 μg mL), and the recoveries of metronidazole are in the range of 96.7-102.2%. Graphical abstract Schematic representation of preparation of non-conjugated polymer carbon dots (PCDs) and detection of metronidazole. Metronidazole with negative charge is easy to produce electrostatic interaction with polyethyleneimine chain with positive charge, which leads to PCDs fluorescence quenching, so as to realize metronidazole detection.

摘要

使用聚乙烯亚胺作为唯一前体制备了荧光量子产率为 9%的非共轭聚合物碳点(PCD)。PCD 的平均尺寸约为 2.1nm,具有蓝色荧光,激发/发射最大值在 380/457nm,可被药物甲硝唑猝灭。该方法在 0.06-15μgmL 甲硝唑浓度范围内具有线性响应,检测限为 20ngmL。在两个水平(0.6 和 5.0μgmL)下对牛奶样品进行了加标,甲硝唑的回收率在 96.7-102.2%范围内。