Are there normal values of phase analysis parameters for left ventricular dyssynchrony in patients with no structural cardiomyopathy?: a systematic review.

作者信息

Marques de Souza Filho Erito, Tinoco Mesquita Claudio, Altenburg Gismondi Ronaldo, de Amorim Fernandes Fernando, Jan Verberne Hein

机构信息

Erito Marques de Souza-Filho Federal Fluminense University (UFF) and Federal Rural University of Rio de Janeiro (UFRRJ).

Claudio Tinoco Mesquita Federal Fluminense University (UFF) and Pro-Cardiaco Hospital, Rio de Janeiro.

出版信息

Nucl Med Commun. 2019 Oct;40(10):980-985. doi: 10.1097/MNM.0000000000001068.

Abstract

BACKGROUND

ECG-gated single photon emission computed tomography (SPECT) myocardial perfusion scintigraphy combined with phase analysis allows for the assessment of left ventricular dyssynchrony. However, there are several software programs available thereby introducing variability in outcome and normal values. The aim of this systematic review was to evaluate the variability between different programs as currently available in literature with a focus on normal values.

METHODS

A systematic review was performed using the Embase, LILACS and Medline databases looking for articles reporting on normal values of the most used phase analysis parameters. The search resulted in 110 articles from Medline, 349 from Embase and one from LILACS. After exclusion of duplicate articles, 370 documents remained. Of these only 13 were deemed eligible for the systematic review.

RESULTS

Phase SD and bandwidth are the main parameters used in dyssynchrony analysis. Most articles reviewed here used the Emory Cardiac ToolBox (ECTb) to determine the phase analysis parameters values, which varied greatly among the four software tested. The bandwidth and phase SD calculated by the Quantitative Gated SPECT (QGS) tends to be smaller than that calculated by the ECTb. In relation to the bandwidth, ECTb and cardioREPO (cREPO) have higher values than the other software programs. The value of entropy obtained from 4DM is lower than those obtained from QGS and cREPO.

CONCLUSION

We found that normal values of phase analysis can vary among software programs and can be different even when the same software is used.

摘要

背景

心电图门控单光子发射计算机断层扫描(SPECT)心肌灌注闪烁显像结合相位分析可用于评估左心室不同步性。然而,有多种软件程序可用,这导致结果和正常值存在差异。本系统评价的目的是评估文献中现有不同程序之间的差异,重点是正常值。

方法

使用Embase、LILACS和Medline数据库进行系统评价,寻找报道最常用相位分析参数正常值的文章。检索结果为来自Medline的110篇文章、来自Embase的349篇文章和来自LILACS的1篇文章。排除重复文章后,剩下370篇文献。其中只有13篇被认为符合系统评价的条件。

结果

相位标准差(SD)和带宽是不同步分析中使用的主要参数。这里回顾的大多数文章使用埃默里心脏工具箱(ECTb)来确定相位分析参数值,在测试的四个软件中这些值差异很大。定量门控SPECT(QGS)计算的带宽和相位SD往往小于ECTb计算的值。关于带宽,ECTb和心脏REPO(cREPO)的值高于其他软件程序。从4DM获得的熵值低于从QGS和cREPO获得的值。

结论

我们发现相位分析的正常值在不同软件程序之间可能有所不同,甚至使用相同软件时也可能不同。