Suppr超能文献

使用门控心肌灌注成像和四个软件程序进行的相位不同步分析比较:基于日本核医学协会工作组正常数据库。

Comparison of phase dyssynchrony analysis using gated myocardial perfusion imaging with four software programs: Based on the Japanese Society of Nuclear Medicine working group normal database.

作者信息

Nakajima Kenichi, Okuda Koichi, Matsuo Shinro, Kiso Keisuke, Kinuya Seigo, Garcia Ernest V

机构信息

Department of Nuclear Medicine, Kanazawa University Hospital, 13-1 Takara-machi, Kanazawa, 920-8641, Japan.

Department of Physics, Kanazawa Medical University, Uchinada, Japan.

出版信息

J Nucl Cardiol. 2017 Apr;24(2):611-621. doi: 10.1007/s12350-015-0333-y. Epub 2016 Feb 9.

Abstract

PURPOSE

Left ventricular (LV) phase dyssynchrony parameters based on gated myocardial perfusion imaging varied among software programs. The aim of this study was to determine normal ranges and factors affecting phase parameters.

METHODS

Normal databases were derived from the Japanese Society of Nuclear Medicine working group (n = 69). The programs were Emory Cardiac Toolbox with SyncTool (ECTb), Quantitative Gated SPECT (QGS), Heart Function View (HFV), and cardioREPO (cREPO); parameters of phase standard deviation (PSD), 95% bandwidth, and entropy were compared with parameters with ECTb as a reference.

RESULTS

PSD (degree) was 5.3 ± 3.3 for QGS (P < .0001), 5.4 ± 2.5 for HFV (P < .0001), and 10.3 ± 3.2 for cREPO (P = n. s.) compared with 11.5 ± 5.5 for ECTb. Phase bandwidth with three programs differed significantly from ECTb. Gender differences were significant for all programs, indicating larger variation in males. After adjustment of LV volumes between genders, the difference disappeared except for QGS. The phase parameters showed wider variations in patients with the lower ejection fraction (EF) and larger LV volumes, depending on software types.

CONCLUSION

Based on normal ranges of phase dyssynchrony parameters in four software programs, dependency on genders, LV volume, and EF should be considered, indicating the need for careful comparison among different software programs.

摘要

目的

基于门控心肌灌注成像的左心室(LV)相位不同步参数在不同软件程序之间存在差异。本研究的目的是确定相位参数的正常范围以及影响这些参数的因素。

方法

正常数据库来自日本核医学协会工作组(n = 69)。所使用的程序有带同步工具的埃默里心脏工具箱(ECTb)、定量门控单光子发射计算机断层扫描(QGS)、心脏功能视图(HFV)和心脏数据库(cREPO);将相位标准差(PSD)、95%带宽和熵的参数与以ECTb为参考的参数进行比较。

结果

与ECTb的11.5±5.5相比,QGS的PSD(度)为5.3±3.3(P <.0001),HFV的为5.4±2.5(P <.0001),cREPO的为10.3±3.2(P =无显著性差异)。三个程序的相位带宽与ECTb有显著差异。所有程序的性别差异均显著,表明男性的变化更大。在调整性别之间的左心室容积后,除QGS外,差异消失。根据软件类型,相位参数在射血分数(EF)较低和左心室容积较大的患者中显示出更大的变化。

结论

基于四个软件程序中相位不同步参数的正常范围,应考虑性别、左心室容积和EF的依赖性,这表明在不同软件程序之间进行仔细比较的必要性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5ac8/5413527/52edf3e37d7c/12350_2015_333_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验