Severity assessment in biomedical research is required by the European authorities. Therefore, a variety of score sheets are available. The first score sheets were designed and introduced by Morton and Griffith (M&G) in 1985, to assess pain and distress in animals. Score sheets are an important part of the 3R principles to evaluate the degree of severity in different studies. Here, we used a modified score sheet from M&G for severity assessment of 12 Aachen minipigs after partial liver resection for safety testing of a novel synthetic sealant (VIVO-107). The control group was treated with the clinical standard fibrin. Estimation of recovery status of both groups was performed from the day of surgery to postoperative day 7 using a score sheet. Included parameters were blood loss during the surgical procedure, general state, spontaneous behaviour and clinical results. Values from 0 to 20 were graded for each category and resulted in the degree of strain (DS) from DS0 to DS4. An increasing DS indicated higher severity. Suitability of the implemented score sheet was evaluated. Higher score points were documented almost exclusively as an outcome of the clinical results, influenced mainly by increased temperature in the fibrin treated control group, whereas, spontaneous behaviour had only slight influence and general state had no influence. The average score seven days after surgery was <2. The laparotomy, where the partial liver resection is a part, is rated as moderate severity in the EU Directive 2010/63, while the assessment done in the present study hints to a mild severity of the model in our hands.
生物医学研究需要对严重程度进行评估,因此出现了各种评分表。最早的评分表由 Morton 和 Griffith(M&G)于 1985 年设计并引入,用于评估动物的疼痛和不适。评分表是评估不同研究中严重程度的 3R 原则的重要组成部分。在这里,我们使用了 M&G 的改良评分表,对 12 头 Aachen 小型猪进行部分肝切除后的严重程度进行评估,这是为了对一种新型合成密封剂(VIVO-107)进行安全性测试。对照组用临床标准纤维蛋白处理。从手术当天到术后第 7 天,使用评分表评估两组的恢复情况。纳入的参数包括手术过程中的失血量、一般状态、自发行为和临床结果。每个类别得分为 0 到 20 分,得出应激程度(DS)从 DS0 到 DS4。DS 越高表示严重程度越高。评估实施的评分表的适用性。评分较高的点几乎完全是临床结果的结果,主要受纤维蛋白处理的对照组体温升高的影响,而自发行为的影响较小,一般状态没有影响。手术后 7 天的平均评分为<2。在欧盟指令 2010/63 中,部分肝切除的剖腹术被评为中度严重程度,而本研究中的评估表明,在我们手中,该模型的严重程度较轻。