Heineberg Luiza de Freitas, Brandão Adriana Buechner de Freitas, Caron Filipe Carlos, Beirith Jaqueline, de Araujo Walter Junior Boim
Faculdades Pequeno Príncipe, Curso Superior de Medicina, Curitiba, PR, Brazil.
Instituto da Circulação - Excelência em Angiologia, Cirurgia Vascular e Endovascular, Departamento de Cirurgia, Curitiba, PR, Brazil.
J Vasc Bras. 2019 Aug 29;18:e20190009. doi: 10.1590/1677-5449.190009.
It is relevant to elucidate the influence that mean linear endovenous energy density (LEED) has on the success of endovenous laser ablation treatment for chronic venous insufficiency, in order to reduce the method's adverse effects.
To evaluate the influence of mean LEED on the prevalence of saphenous closure 30 days after the laser ablation procedure.
153 lower limbs from 118 patients seen at a tertiary hospital and treated for chronic venous insufficiency with endovenous 1470 nm laser ablation under local anesthesia were evaluated. The mean LEED used to treat patients was calculated to determine whether greater than average LEED was required for treatment success.
A significant difference (p = 0.021) in saphenofemoral junction closure was associated with mean LEED used above the knee. Conversely, there was no significant difference in the thigh segment.
Linear intravenous energy density greater than the mean of 70.57 J/cm was associated with a higher rate of closure at the saphenofemoral junction. However, density did not have an influence on the result for the thigh segment, showing that an energy density exceeding 70.57 J/cm tends not to be required for treatment of this segment.
为减少该方法的不良反应,阐明平均线性静脉能量密度(LEED)对慢性静脉功能不全的静脉腔内激光消融治疗成功率的影响具有重要意义。
评估平均LEED对激光消融术后30天隐静脉闭合率的影响。
对一家三级医院的118例接受局部麻醉下1470nm静脉腔内激光消融治疗慢性静脉功能不全的患者的153条下肢进行评估。计算用于治疗患者的平均LEED,以确定治疗成功是否需要高于平均水平的LEED。
隐股静脉交界处闭合情况存在显著差异(p = 0.021),与膝上使用的平均LEED相关。相反,大腿段无显著差异。
线性静脉能量密度大于平均70.57 J/cm与隐股静脉交界处较高的闭合率相关。然而,能量密度对大腿段的治疗结果没有影响,表明治疗该段往往不需要超过70.57 J/cm的能量密度。