超声心动图自动测量二尖瓣环运动组织多普勒指数的正常范围。来自HUNT3研究的数据。

Normal ranges for automatic measurements of tissue Doppler indices of mitral annular motion by echocardiography. Data from the HUNT3 Study.

作者信息

Grue Jahn Frederik, Storve Sigurd, Støylen Asbjørn, Torp Hans, Haugen Bjørn Olav, Mølmen Harald Edvard, Dalen Håvard

机构信息

Department of Circulation and Medical Imaging, Faculty of Medicine and Health Sciences, Norwegian University of Science and Technology (NTNU), Trondheim, Norway.

Clinic of Cardiology, St. Olavs hospital, Trondheim University Hospital, Trondheim, Norway.

出版信息

Echocardiography. 2019 Sep;36(9):1646-1655. doi: 10.1111/echo.14476. Epub 2019 Sep 23.

Abstract

BACKGROUND

Automatic quantification of left ventricular (LV) function could enhance workflow for cardiologists and assist inexperienced clinicians who perform focused cardiac ultrasound. We have developed an algorithm for automatic measurements of the mitral annular plane systolic excursion (MAPSE) and peak velocities in systole (S') and early (e') and late (a') diastole. We aimed to establish normal reference values for the automatic measurements and to compare them with manual measurements.

METHODS AND RESULTS

Healthy participants (n = 1157, 52.5% women) from the HUNT3 cross-sectional population study in Norway were included. The mean age ± standard deviation (SD) was 49 ± 14 (range: 19-89) years. The algorithm measured MAPSE, S', e', and a' from apical 4-chamber color tissue Doppler imaging (cTDI) recordings. The manual measurements were obtained by two echocardiographers, who measured MAPSE by M-mode and the velocities by cTDI. For men and women, age-specific reference values were created for groups (mean ± 1.96SD) and by linear regression (mean, 95% prediction interval). Age was negatively correlated with MAPSE, S', and e' and positively correlated with a'. There were small differences between genders. Normal reference ranges were created. The coefficients of variation between automatic and manual measurements ranged from 5.5% (S') to 11.7% (MAPSE).

CONCLUSION

Normal reference values for automatic measurements of LV function indices are provided. The automatic measurements were in line with the manual measurements. Implementing automatic measurements and comparison with normal ranges in ultrasound scanners can allow for quick and precise interpretation of LV function.

摘要

背景

左心室(LV)功能的自动量化可优化心脏病专家的工作流程,并帮助进行心脏超声检查的经验不足的临床医生。我们开发了一种算法,用于自动测量二尖瓣环平面收缩期位移(MAPSE)以及收缩期(S')、舒张早期(e')和舒张晚期(a')的峰值速度。我们旨在建立自动测量的正常参考值,并将其与手动测量值进行比较。

方法与结果

纳入了挪威HUNT3横断面人群研究中的健康参与者(n = 1157,52.5%为女性)。平均年龄±标准差(SD)为49±14(范围:19 - 89)岁。该算法从心尖四腔彩色组织多普勒成像(cTDI)记录中测量MAPSE、S'、e'和a'。手动测量由两名超声心动图医生进行,他们通过M型测量MAPSE,通过cTDI测量速度。针对男性和女性,通过分组(均值±1.96SD)和线性回归(均值,95%预测区间)创建了年龄特异性参考值。年龄与MAPSE、S'和e'呈负相关,与a'呈正相关。性别之间存在细微差异。创建了正常参考范围。自动测量与手动测量之间的变异系数范围为5.5%(S')至11.7%(MAPSE)。

结论

提供了左心室功能指标自动测量的正常参考值。自动测量与手动测量结果一致。在超声扫描仪中实施自动测量并与正常范围进行比较,可以快速、准确地解读左心室功能。