The indications for the use of intramedullary (IM) nails have been extended to include extra-articular distal metaphyseal tibia fractures. We hypothesize that interfragmentary motion during physiologic compressive loading of distal tibia fractures is influenced by fracture obliquity and can be modulated by interlocking screw configuration. Sawbone specimens were osteotomized with frontal plane obliquities ranging from 0° to 60° and then fixed by IM nailing with six interlocking screw configurations. Interfragmentary motion was evaluated during loading in axial compression to 1000 N. Comparisons of interfragmentary motions were made (1) between configurations for the various fracture obliquities and (2) between fracture obliquities for the various screw configurations using a mixed-effects regression model. As the degree of fracture obliquity increased, significantly more interfragmentary displacement was shown in configurations with two distal interlocking screws and one proximal screw set in dynamic mode. Fracture obliquity beyond 30° causes demonstrated instability in configurations with less than two distal locking screws and one proximal locking screw. Optimizing the available screw configurations can minimize fracture site motion and shear in distal tibial fractures with larger fracture obliquities.

摘要

髓内钉的使用指征已扩展至包括胫骨远端干骺端关节外骨折。我们推测,胫骨远端骨折在生理压缩负荷下的骨折块间运动受骨折倾斜度影响,且可通过交锁螺钉配置进行调节。将Sawbone标本在额状面以0°至60°的倾斜度截骨,然后采用六种交锁螺钉配置通过髓内钉固定。在轴向压缩至1000 N的加载过程中评估骨折块间运动。使用混合效应回归模型对骨折块间运动进行比较:(1) 各种骨折倾斜度的配置之间;(2) 各种螺钉配置的骨折倾斜度之间。随着骨折倾斜度增加,在动态模式下设置两个远端交锁螺钉和一个近端螺钉的配置中,骨折块间位移明显更多。超过30°的骨折倾斜度在少于两个远端锁定螺钉和一个近端锁定螺钉的配置中表现出不稳定。优化可用的螺钉配置可使骨折倾斜度较大的胫骨远端骨折的骨折部位运动和剪切最小化。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验