Fischer T, Rystedt I
Contact Dermatitis. 1985 Feb;12(2):93-8. doi: 10.1111/j.1600-0536.1985.tb01060.x.
853 hard metal workers were patch tested with nickel sulphate 5%, potassium dichromate 0.5% and cobalt chloride 1%, each in petrolatum. Non-allergic reactions appeared in 6.5% of the nickel tests, 13% of the chromium tests and 18.3% of the cobalt tests. Most of the individuals with positive, poral or pustular reactions were retested with serial dilutions of metal salts in pet. and in water. The accuracy of a positive initial nickel reaction was 83%, a chromium reaction 40% and a cobalt reaction 62%. The nonallergic reactions were partly reproducible and correlated with both the type of patch test material and with individual factors. Weak and moderately strong positive patch test reactions to metal salts may be irritant and should be checked with serial dilution tests or at least be retested. A reduction of the cobalt chloride concentration from 1% to 0.5% in the standard test material is discussed.
853名硬质合金工人用5%硫酸镍、0.5%重铬酸钾和1%氯化钴的凡士林制剂进行了斑贴试验。镍试验中6.5%、铬试验中13%以及钴试验中18.3%出现了非过敏反应。大多数出现阳性、丘疹或脓疱反应的个体用金属盐在凡士林和水中的系列稀释液进行了重新检测。初始镍反应阳性的准确率为83%,铬反应为40%,钴反应为62%。非过敏反应部分可重现,且与斑贴试验材料类型及个体因素均相关。对金属盐的弱阳性和中等强度阳性斑贴试验反应可能是刺激性的,应通过系列稀释试验进行检查,或至少重新检测。讨论了将标准试验材料中氯化钴浓度从1%降至0.5%的问题。