University of Massachusetts Medical School, Worcester.
Department of Ophthalmology, Massachusetts Eye and Ear Infirmary.
J Glaucoma. 2019 Nov;28(11):979-988. doi: 10.1097/IJG.0000000000001381.
PRéCIS:: Neuroretinal rim minimum distance band (MDB) thickness is significantly lower in older subjects and African Americans compared with whites. It is similar in both sexes.
To evaluate the relationship between age, race, and sex with the neuroretinal rim using high-density spectral-domain optical coherence tomography optic nerve volume scans of normal eyes.
A total of 256 normal subjects underwent Spectralis spectral-domain optical coherence tomography optic nerve head volume scans. One eye was randomly selected and analyzed for each subject. Using custom-designed software, the neuroretinal rim MDB thickness was calculated from volume scans, and global and quadrant neuroretinal rim thickness values were determined. The MDB is a 3-dimensional neuroretinal rim band comprised of the shortest distance between the internal limiting membrane and the termination of the retinal pigment epithelium/Bruch's membrane complex. Multiple linear regression analysis was performed to determine the associations of age, race, and sex with neuroretinal rim MDB measurements.
The population was 57% female and 69% white with a mean age of 58.4±15.3 years. The mean MDB thickness in the normal population was 278.4±47.5 µm. For this normal population, MDB thickness decreased by 0.84 µm annually (P<0.001). African Americans had thinner MDBs compared with whites (P=0.003). Males and females had similar MDB thickness values (P=0.349).
Neuroretinal rim MDB thickness measurements decreased significantly with age. African Americans had thinner MDB neuroretinal rims than whites.
目的:使用高分辨率频域光学相干断层扫描视神经体积扫描评估正常眼的年龄、种族和性别与神经视网膜边缘的关系。
方法:共有 256 名正常受试者接受了 Spectralis 频域光学相干断层扫描视神经头体积扫描。为每位受试者随机选择一只眼睛进行分析。使用定制设计的软件,从体积扫描中计算神经视网膜边缘最小距离带(MDB)厚度,并确定全局和象限神经视网膜边缘厚度值。MDB 是一个 3 维神经视网膜边缘带,由内界膜和视网膜色素上皮/布鲁赫膜复合体终止之间的最短距离组成。采用多元线性回归分析确定年龄、种族和性别与神经视网膜边缘 MDB 测量值的关系。
结果:该人群中女性占 57%,白人占 69%,平均年龄为 58.4±15.3 岁。正常人群的平均 MDB 厚度为 278.4±47.5 μm。对于这个正常人群,MDB 厚度每年减少 0.84 μm(P<0.001)。与白人相比,非裔美国人的 MDB 较薄(P=0.003)。男性和女性的 MDB 厚度值相似(P=0.349)。
结论:神经视网膜边缘 MDB 厚度随年龄显著下降。非裔美国人的神经视网膜边缘 MDB 比白人薄。