Dehydration assessment via a portable, single sided magnetic resonance sensor.

作者信息

Bashyam Ashvin, Frangieh Chris J, Li Matthew, Cima Michael J

机构信息

David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, Massachusetts.

Department of Electrical Engineering & Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts.

出版信息

Magn Reson Med. 2020 Apr;83(4):1390-1404. doi: 10.1002/mrm.28004. Epub 2019 Oct 21.


DOI:10.1002/mrm.28004
PMID:31631380
Abstract

PURPOSE: Undiagnosed dehydration compromises health outcomes across many populations. Existing dehydration diagnostics require invasive bodily fluid sampling or are easily confounded by fluid and electrolyte intake, environment, and physical activity limiting widespread adoption. We present a portable MR sensor designed to measure intramuscular fluid shifts to identify volume depletion. METHODS: Fluid loss is induced via a mouse model of thermal dehydration (37°C; 15-20% relative humidity). We demonstrate quantification of fluid loss induced by hyperosmotic dehydration with multicomponent T2 relaxometry using both a benchtop NMR system and MRI localized to skeletal muscle tissue. We then describe a miniaturized (1000 cm ) portable (4 kg) MR sensor (0.28 T) designed to identify dehydration-induced fluid loss. T2 relaxometry measurements were performed using a Carr-Purcell-Meiboom-Gill pulse sequence in ~4 min. RESULTS: T2 values from the portable MR sensor exhibited strong (R = 0.996) agreement with benchtop NMR spectrometer. Thermal dehydration induced weight loss of 4 to 11% over 5 to 10 h. Fluid loss induced by thermal dehydration was accurately identified via whole-animal NMR and skeletal muscle. The portable MR sensor accurately identified dehydration via multicomponent T2 relaxometry. CONCLUSION: Performing multicomponent T2 relaxometry localized to the skeletal muscle with a miniaturized MR sensor provides a noninvasive, physiologically relevant measure of dehydration induced fluid loss in a mouse model. This approach offers sensor portability, reduced system complexity, fully automated operation, and low cost compared with MRI. This approach may serve as a versatile and portable point of care technique for dehydration monitoring.

摘要

相似文献

[1]
Dehydration assessment via a portable, single sided magnetic resonance sensor.

Magn Reson Med. 2020-4

[2]
Single-Sided Magnet System for Quantitative MR Relaxometry and Preclinical In-Vivo Monitoring.

IEEE Trans Biomed Eng. 2023-2

[3]
Transverse relaxation-based assessment of mammographic density and breast tissue composition by single-sided portable NMR.

Magn Reson Med. 2019-4-29

[4]
(1)H nuclear magnetic resonance (NMR) as a tool to measure dehydration in mice.

NMR Biomed. 2015-8

[5]
A portable single-sided magnetic-resonance sensor for the grading of liver steatosis and fibrosis.

Nat Biomed Eng. 2021-3

[6]
A low cost, portable NMR probe for high pressure, MR relaxometry.

J Magn Reson. 2019-5-2

[7]
Single-sided magnetic resonance-based sensor for point-of-care evaluation of muscle.

Nat Commun. 2024-1-10

[8]
Pulsed NMR relaxometry of striated muscle fibers.

Magn Reson Med. 1991-10

[9]
Portable NMR for quantification of breast density in vivo: Proof-of-concept measurements and comparison with quantitative MRI.

Magn Reson Imaging. 2022-10

[10]
Sensing mammographic density using single-sided portable Nuclear Magnetic Resonance.

Saudi J Biol Sci. 2022-4

引用本文的文献

[1]
A Review on In Vivo Research Dehydration Models and Application of Rehydration Strategies.

Nutrients. 2024-10-21

[2]
Single-sided magnetic resonance-based sensor for point-of-care evaluation of muscle.

Nat Commun. 2024-1-10

[3]
Deep neural-network based optimization for the design of a multi-element surface magnet for MRI applications.

Inverse Probl. 2022-1-26

[4]
Oxygen saturation-dependent effects on blood transverse relaxation at low fields.

MAGMA. 2022-10

[5]
A portable single-sided magnetic-resonance sensor for the grading of liver steatosis and fibrosis.

Nat Biomed Eng. 2021-3

[6]
Magneto-Impedance Biosensor Sensitivity: Effect and Enhancement.

Sensors (Basel). 2020-9-12

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

推荐工具

医学文档翻译智能文献检索