Department of Clinical Laboratory, Beijing Chao-Yang Hospital, Capital Medical University, Beijing, China.
Department of Clinical Laboratory, Ophthalmological Hospital, Chinese Academy of Traditional Chinese Medicine, Beijing, China.
Scand J Clin Lab Invest. 2019 Dec;79(8):579-583. doi: 10.1080/00365513.2019.1680860. Epub 2019 Oct 30.
A standardized reference method is needed to accurately and precisely measure urine-formed elements (UFEs; red blood cells [RBCs], white blood cells [WBCs], and squamous epithelial cells [sECs]). We compared the results from a standard method with those from an automated analyzer. Trained technicians used standardized bright-field microscopy of fresh non-centrifuged urine samples, and disposable 1 µl chambers. Fifteen experienced technicians from 5 hospitals (3 per hospital) each performed 6 manual counts of 10 different native urine samples using a manual chamber and standard methods. The sEC counts were at least 50/µL, and the coefficient of variation (CV) was less than 14%; the RBC and WBC counts were at least 200/µL and the CVs were less than 7%. The same samples were also analyzed 6 times using automated analyzers. The means, CVs, and biases were determined. The median CVs for the manual measurements were 6.4% (WBCs), 6.6% (RBCs), and 12.7% (sECs). The CVs of the automated analyzer were 4.7% (WBCs), 5.6% (RBCs), and 9.2% (sECs). Biases between the automated and manual methods were -2.9% to 5.0%(WBCs), -0.8% to 8.8% (RBCs) and -2.8% to 9.4% (sECs). The count mean values and expanded uncertainties of these counts were (224.5 ± 15.0) cells/µL, (234.2 ± 16.2) cells/µL, and (61.5 ± 7.9) cells/µL, respectively. The standardized manual method for measuring UFEs had high precision and accuracy, making it a suitable reference method. Use of this reference method to calibrate an automated analyzer improved the accuracy of automated analysis.
需要一种标准化的参考方法来准确、精确地测量尿形成元素(UFEs;红细胞 [RBCs]、白细胞 [WBCs] 和鳞状上皮细胞 [sECs])。我们比较了标准方法和自动分析仪的结果。经过培训的技术人员使用新鲜非离心尿液样本的标准化明场显微镜和一次性 1 μl 室进行检测。来自 5 家医院的 15 名经验丰富的技术人员(每家医院 3 名)每人使用手动室和标准方法对 10 种不同的天然尿液样本进行 6 次手动计数。sEC 计数至少为 50/μL,变异系数(CV)小于 14%;RBC 和 WBC 计数至少为 200/μL,CV 小于 7%。同样的样本也使用自动分析仪分析了 6 次。确定了平均值、CV 和偏差。手动测量的中位数 CV 分别为 6.4%(WBCs)、6.6%(RBCs)和 12.7%(sECs)。自动分析仪的 CV 分别为 4.7%(WBCs)、5.6%(RBCs)和 9.2%(sECs)。自动和手动方法之间的偏差为 -2.9% 至 5.0%(WBCs)、-0.8% 至 8.8%(RBCs)和 -2.8% 至 9.4%(sECs)。这些计数的计数平均值和扩展不确定度分别为(224.5±15.0)细胞/μL、(234.2±16.2)细胞/μL 和(61.5±7.9)细胞/μL。用于测量 UFEs 的标准化手动方法具有高精度和准确性,是一种合适的参考方法。使用此参考方法校准自动分析仪可提高自动分析的准确性。