Suppr超能文献

荧光成像系统的综合表征方法

Comprehensive characterization method for a fluorescence imaging system.

作者信息

Mela Christopher, Liu Yang

出版信息

Appl Opt. 2019 Oct 20;58(30):8237-8246. doi: 10.1364/AO.58.008237.

Abstract

Fluorescence imaging systems are regularly characterized by their ability to distinguish varying concentrations of fluorophores in a solution or tissue phantom. However, there is inadequate standardization in the field for fluorescence characterization. In this study, we characterize a fluorescence imaging system developed for pathogen detection, regarding its ability to detect a near-infrared dye. During this process, we vary a number of key factors involved in fluorescence imaging, such as the excitation intensity, background level, working distance, volume of fluorescent solution, and type of container used to hold the fluorescent solution. We then analyze the results, with statistical rigor, to determine which factors result in significant changes in fluorescence detection. Notably, we found that using different types of containers to hold the dye solution can have a significant impact on fluorescence detection, while the effects of working distance and excitation intensity can vary. Based on our findings, greater standardization, or at least more thorough reporting of the experimental setup, is recommended to researchers when publishing characterization results of new imaging systems.

摘要

荧光成像系统通常通过其区分溶液或组织模型中不同浓度荧光团的能力来表征。然而,荧光表征领域的标准化不足。在本研究中,我们对一种为病原体检测而开发的荧光成像系统进行表征,考察其检测近红外染料的能力。在此过程中,我们改变了荧光成像中涉及的一些关键因素,如激发强度、背景水平、工作距离、荧光溶液体积以及用于盛放荧光溶液的容器类型。然后,我们进行严谨的统计分析结果,以确定哪些因素会导致荧光检测出现显著变化。值得注意的是,我们发现使用不同类型的容器盛放染料溶液会对荧光检测产生显著影响,而工作距离和激发强度的影响可能有所不同。基于我们的研究结果,建议研究人员在发表新成像系统的表征结果时,进行更大程度的标准化,或者至少更全面地报告实验设置。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验