Suppr超能文献

跟腱与腓肠肌僵硬度的性别差异研究:观察者间可靠性、日间重复性及踝关节运动的影响

An investigation of the sex-related differences in the stiffness of the Achilles tendon and gastrocnemius muscle: Inter-observer reliability and inter-day repeatability and the effect of ankle joint motion.

作者信息

Taş Serkan, Salkın Yasemin

机构信息

Toros University, School of Health Sciences, Department of Physiotherapy and Rehabilitation, 33140, Mersin, Turkey.

Toros University, School of Health Sciences, Department of Physiotherapy and Rehabilitation, 33140, Mersin, Turkey.

出版信息

Foot (Edinb). 2019 Dec;41:44-50. doi: 10.1016/j.foot.2019.09.003. Epub 2019 Sep 29.

Abstract

PURPOSE

The purpose of the present study was to investigate sex-related differences in the stiffness of the Achilles tendon and gastrocnemius muscle at rest and tensioned state. Another purpose of the study was to investigate the inter-observer reliability and inter-day repeatability of MyotonPRO, a portable myotonometer, in measuring tendon and muscle stiffness.

METHODS

The study included 73 healthy participants (19 males for the reliability and repeatability study; 24 males and 30 females for the experimental study) with an age range of 19-27 years. The stiffness of the Achilles tendon and medial gastrocnemius muscle was measured with a portable myotonometer (MyotonPRO). The stiffness measurements of the Achilles tendon and medial gastrocnemius muscle were performed at 0° and 10° of ankle joint dorsiflexion. The stiffness measurements were performed by two physiotherapists to determine the inter-observer reliability of the device. For the inter-day repeatability (or between-day precision), the same individuals were reassessed by the same examiner after a 3-day interval.

RESULTS

It was found that MyotonPRO has excellent inter-observer reliability and inter-day repeatability in measuring the stiffness of the Achilles tendon and medial gastrocnemius muscle (ICC=0.83-0.98). The stiffness of the Achilles tendon and gastrocnemius muscle at neutral and 10° joint dorsiflexion was higher in males compared to females (p<0.05); however, the stiffness value of difference between neutral and 10° joint dorsiflexion for the Achilles tendon and gastrocnemius muscle was similar in both groups (p>0.05).

DISCUSSION

The obtained results suggest that MyotonPRO is a reliable and repeatable device in measuring the stiffness of the Achilles tendon and gastrocnemius muscle. Furthermore, males have stiffer Achilles tendon and gastrocnemius muscle, compared to females; however, the change in the stiffness of the assessed tissues caused by joint motion was similar in both sexes.

摘要

目的

本研究的目的是调查跟腱和腓肠肌在静息和紧张状态下的刚度的性别差异。本研究的另一个目的是调查便携式肌张力计MyotonPRO在测量肌腱和肌肉刚度方面的观察者间可靠性和日间重复性。

方法

该研究纳入了73名年龄在19至27岁之间的健康参与者(19名男性用于可靠性和重复性研究;24名男性和30名女性用于实验研究)。使用便携式肌张力计(MyotonPRO)测量跟腱和腓肠肌内侧的刚度。在踝关节背屈0°和10°时进行跟腱和腓肠肌内侧的刚度测量。由两名物理治疗师进行刚度测量,以确定该设备的观察者间可靠性。对于日间重复性(或日间精密度),在间隔3天后由同一名检查者对相同个体进行重新评估。

结果

发现MyotonPRO在测量跟腱和腓肠肌内侧的刚度方面具有出色的观察者间可靠性和日间重复性(ICC = 0.83 - 0.98)。男性在中立位和关节背屈10°时跟腱和腓肠肌的刚度高于女性(p < 0.05);然而,两组中跟腱和腓肠肌在中立位和关节背屈10°之间的刚度差值相似(p > 0.05)。

讨论

获得的结果表明,MyotonPRO是一种测量跟腱和腓肠肌刚度的可靠且可重复的设备。此外,与女性相比,男性的跟腱和腓肠肌更硬;然而,两性中关节运动引起的被评估组织刚度变化相似。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验