Luoyang Orthopedic Hospital of Henan Province, Orthopedic Hospital of Henan Province, Luoyang, China.
Clinical College of Acupuncture, Moxibustion and Rehabilitation, Guangzhou University of Chinese Medicine, Guangzhou, China.
Sci Rep. 2018 Nov 20;8(1):17064. doi: 10.1038/s41598-018-34719-7.
The purposes of this study were to compare Young's modulus values determined by shear wave ultrasound elastography (SWUE) with stiffness index obtained using a hand-held MyotonPRO device on the resting stiffness of gastrocnemius muscle belly and Achilles tendon; and to examine the test-retest reliability of those stiffness measurement using hand-held MyotonPRO. Twenty healthy volunteers participated in the study. The measurement values of muscle and tendon was determined in dominant legs. Each marker point was assessed using MyotonPRO and SWUE, respectively. Intra-operator reliability of MyotonPRO was established in 10 of the subjects. The correlation coefficients between the values of muscle and tendon stiffness indices determined by MyotonPRO and SWUE were calculated. Significant correlations were found for muscle and tendon stiffness and Young's modulus ranged from 0.463 to 0.544 (all P < 0.05). The intra-operator reliability ranged from good to excellent (ICC = 0.787~0.928). These results suggest that the resting stiffness of gastrocnemius muscle belly and Achilles tendon measured by MyotonPRO is related to the Young's modulus of those quantified by SWUE. The MyotonPRO shows good intra-operator repeatability. Therefore, the present study shows that MyotonPRO can be used to assess mechanical properties of gastrocnemius muscle belly and Achilles tendon with a resting condition.
本研究旨在比较剪切波超声弹性成像(SWUE)测定的杨氏模量值与手持 MyotonPRO 设备测定的跟腱和腓肠肌腹静息硬度的刚度指数,并检验手持 MyotonPRO 测量这些硬度的重测信度。20 名健康志愿者参与了本研究。使用 MyotonPRO 和 SWUE 分别确定优势腿的肌肉和肌腱的测量值。使用 MyotonPRO 和 SWUE 分别评估每个标记点。在 10 名受试者中建立了 MyotonPRO 的操作者内可靠性。计算了由 MyotonPRO 和 SWUE 确定的肌肉和肌腱刚度指数值之间的相关系数。肌肉和肌腱硬度与杨氏模量的相关系数为 0.4630.544(均 P<0.05)。操作者内可靠性范围为良好到优秀(ICC=0.7870.928)。这些结果表明,MyotonPRO 测量的腓肠肌腹和跟腱的静息硬度与 SWUE 定量的杨氏模量有关。MyotonPRO 显示出良好的操作者内可重复性。因此,本研究表明 MyotonPRO 可用于评估静息状态下的腓肠肌腹和跟腱的力学特性。