Polich J
Division of Preclinical Neuroscience and Endocrinology, Research Institute of Scripps Clinic, La Jolla, California 92037.
J Clin Neurophysiol. 1988 Jul;5(3):287-94.
The P300 (P3) component of the event-related brain potential (ERP) was elicited with an auditory discrimination paradigm in a large group (n = 100) of undergraduates. Subjects who displayed bifurcated P3 peaks across trial blocks (n = 35) were classified into three groups based on the consistency of the replication of the two P3 subpeaks. Amplitude and latency measures for the first (P3a) and second (P3b) peaks from each subject demonstrated no statistically reliable differences between groups. Both subcomponents increased in amplitude from the frontal to parietal electrode sites, although the earlier peak was smaller at the frontal electrode site for the second compared to first trial block. The largest P3 peak for each trial block (P3MAX) from each subject was measured and produced amplitude and latency values that closely matched normative data from the same paradigm. The findings suggested that the P3a and P3b subcomponents from auditory stimuli may be distributed in the population in an asymmetric fashion, and that the P3MAX measurement technique provides a reasonable means of assessing amplitude and latency values from individuals with bifurcated peaks.
在一大组(n = 100)本科生中,采用听觉辨别范式诱发事件相关脑电位(ERP)的P300(P3)成分。在各试验块中显示出双峰P3峰值的受试者(n = 35)根据两个P3子峰重复出现的一致性被分为三组。对每个受试者的第一个(P3a)和第二个(P3b)峰值的幅度和潜伏期测量结果显示,各组之间在统计学上没有可靠的差异。两个子成分从额叶电极部位到顶叶电极部位的幅度均增加,尽管与第一个试验块相比,第二个试验块中较早出现的峰值在额叶电极部位较小。测量了每个受试者每个试验块的最大P3峰值(P3MAX),得出的幅度和潜伏期值与同一范式的标准数据密切匹配。研究结果表明,来自听觉刺激的P3a和P3b子成分在人群中的分布可能是不对称的,并且P3MAX测量技术为评估具有双峰的个体的幅度和潜伏期值提供了一种合理的方法。