Oz Isilay, Hizal Evren, Cam Osman Halit, Ozluoglu Levent Naci
Department of Otolaryngology, Faculty of Medicine, Baskent University, Ankara, Turkey,
Department of Otolaryngology, Faculty of Medicine, Baskent University, Ankara, Turkey.
Audiol Neurootol. 2019;24(6):285-292. doi: 10.1159/000503845. Epub 2019 Nov 12.
To evaluate resonance frequency (RF) values via dehydration effects in the inner ear caused by the glycerol test, which is used as a diagnostic method for Ménière's disease (MD).
Twenty adult patients with unilateral MD were included in the study. Before, and then at 1, 2, and 3 h after administration of glycerol (1 g/kg), pure-tone hearing levels (125-8,000 kHz) and multifrequency tympanometry tests were performed. As a control, the RF values of the ears of 25 healthy subjects (i.e., 50 ears) were compared to the affected and unaffected ears in the 20 MD patients.
There was a significant difference between the RF values of affected and healthy ears before glycerol administration (p = 0.047). The RF values before and after glycerol administration into affected ears were compared. The average RF values decreased significantly from 748.0 ± 402.1 to 808.0 ± 410.1 Hz at 1 h after glycerol intake, and this value increased during the subsequent hours. There were no statistically significant differences between the pure-tone levels before and 1 h after glycerol administration, but a significant decrease was observed at 3 h.
We suggest that MD has different inner-ear dynamics and normal RF values when compared to healthy ears. Furthermore, decreased inner ear pressure causes reduction of the mass effect and a stiffening of the annular ligament. We conclude that pre- and post-RF tests should be added to the test battery for diagnosis of MD.
通过甘油试验对内耳造成的脱水效应来评估共振频率(RF)值,甘油试验用作梅尼埃病(MD)的诊断方法。
本研究纳入了20例单侧MD成年患者。在给予甘油(1 g/kg)之前,以及给药后1、2和3小时,进行纯音听力水平(125 - 8000 kHz)和多频鼓室图测试。作为对照,将25名健康受试者(即50只耳)的耳朵的RF值与20例MD患者的患耳和未患耳进行比较。
在给予甘油之前,患耳与健康耳的RF值之间存在显著差异(p = 0.047)。比较了患耳给予甘油前后的RF值。甘油摄入后1小时,平均RF值从748.0 ± 402.1 Hz显著下降至808.0 ± 410.1 Hz,且该值在随后的时间内升高。甘油给药前和给药后1小时的纯音水平之间无统计学显著差异,但在3小时时观察到显著下降。
我们认为,与健康耳相比,MD具有不同的内耳动力学和正常的RF值。此外,内耳压力降低会导致质量效应降低和环形韧带变硬。我们得出结论,RF测试前和测试后应添加到MD诊断的测试组中。