多频鼓室导抗图对梅尼埃病的诊断价值

Diagnostic usefulness of multifrequency tympanometry for Ménière's disease.

作者信息

Sugasawa Keiko, Iwasaki Shinichi, Fujimoto Chisato, Kinoshita Makoto, Inoue Aki, Egami Naoya, Ushio Munetaka, Chihara Yasuhiro, Yamasoba Tatsuya

机构信息

Department of Otolaryngology, Faculty of Medicine, University of Tokyo, Tokyo, Japan.

出版信息

Audiol Neurootol. 2013;18(3):152-60. doi: 10.1159/000346343. Epub 2013 Feb 1.

Abstract

Multifrequency tympanometry (MFT) is the measurement of the impedance of the middle ear transmission system at a wide range of frequencies from 200 Hz to 2 kHz. A potential use of MFT as a new diagnostic tool for detecting endolymphatic hydrops has recently been reported. However, its clinical usefulness for diagnosing Ménière's disease (MD) remains unclear. To evaluate the clinical usefulness of MFT as a new qualitative and diagnostic test for MD, we performed MFT in 70 patients with unilateral or bilateral MD and in 29 normal control subjects. The width of double peaks in the admittance tympanograms (Y width) at 2 kHz and the resonance frequency (RF) were analyzed, and receiver operating characteristic (ROC) curves were constructed. The Y width in MD-affected ears was significantly greater than that in control ears (p < 0.001). The RF in MD-affected ears was significantly lower than that in control ears (p < 0.01). Neither the Y width nor RF had a significant relationship with hearing levels or the results of caloric and vestibular myogenic potential testings. The area under the ROC curve was 0.71 for the Y width and 0.66 for the RF. At the optimal cutoff points, the sensitivity and specificity of the Y width were 47.3 and 86.8%, respectively, and those of the RF were 41.3 and 84.2%, respectively. These results indicated that MFT is significantly associated with the presence of MD, but its diagnostic accuracy is only modest. MFT is a simple, noninvasive test, which should be considered as a complementary test in the diagnosis of MD.

摘要

多频鼓室声导抗测试(MFT)是在200赫兹至2千赫兹的宽频率范围内测量中耳传音系统的阻抗。最近有报道称MFT有可能作为检测内淋巴积水的一种新的诊断工具。然而,其对梅尼埃病(MD)的临床诊断价值仍不明确。为了评估MFT作为MD一种新的定性和诊断测试的临床价值,我们对70例单侧或双侧MD患者以及29名正常对照者进行了MFT测试。分析了2千赫兹时导纳鼓室图中的双峰宽度(Y宽度)和共振频率(RF),并绘制了受试者工作特征(ROC)曲线。患MD耳的Y宽度显著大于对照耳(p<0.001)。患MD耳的RF显著低于对照耳(p<0.01)。Y宽度和RF与听力水平、冷热试验及前庭肌源性电位测试结果均无显著相关性。Y宽度的ROC曲线下面积为0.71,RF的为0.66。在最佳截断点时,Y宽度的敏感性和特异性分别为47.3%和86.8%,RF的敏感性和特异性分别为41.3%和84.2%。这些结果表明MFT与MD的存在显著相关,但其诊断准确性仅为中等。MFT是一种简单、无创的测试,应被视为MD诊断中的一种补充测试。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验