Department of Orthopaedic Surgery, Peking Union Medical College Hospital, Peking Union Medical College, Beijing, 100730, China.
Peking Union Medical College, Beijing, 100730, China.
J Orthop Surg Res. 2019 Nov 27;14(1):388. doi: 10.1186/s13018-019-1410-8.
The ideal bearing surface for patients of avascular necrosis (AVN) undergoing total hip arthroplasty (THA) remains controversial. The purpose of this study is to evaluate the clinical outcomes, health-related quality of life (HRQL), and wear of the bearing surface between ceramic-on-ceramic (CoC) and ceramic-on-highly cross-linked polyethylene (CoXPE) THA for patients of AVN after midterm follow-up.
We performed a retrospective case-control analysis of 93 CoC and 77 CoXPE consecutive THAs for patients of AVN. The cases were followed at a minimum 5 years follow-up (average 7 years). Harris hip score (HHS) score and bearing-related complications were assessed. The health-related quality of life (HRQL) was assessed with the Short Form 36 (SF-36). Plain radiographs and computed tomography (CT) were used for radiographic evaluation.
Both the CoC group and CoXPE group showed statistically significant improvements in HHS scores with no difference between the two bearing surfaces. There was no significant difference as for SF-36 at the latest follow-up between two groups, except for significant higher scores in the dimensions of general health in the CoC group (75.7 vs 64.7, P = 0.032). No radiographic evidence of osteolysis and loosening was present at the final follow-up. The mean wear rate of the CoC was 0.0096 mm/year and the CoXPE was 0.047 mm/year after evaluation with reconstructed CT.
CoC THAs acts as well as CoXPE THAs for patients with femoral head avascular necrosis after midterm follow-up. CoC bearing can significantly decrease the wearing rate than CoXPE bearing.
对于接受全髋关节置换术(THA)的股骨头坏死(AVN)患者,理想的关节面仍存在争议。本研究旨在评估中短期随访后 AVN 患者行陶瓷对陶瓷(CoC)和陶瓷对超高交联聚乙烯(CoXPE)THA 的临床结果、健康相关生活质量(HRQL)和关节面磨损情况。
我们对 93 例 CoC 和 77 例 CoXPE 连续 THA 进行回顾性病例对照分析,AVN 患者随访时间至少为 5 年(平均 7 年)。评估 Harris 髋关节评分(HHS)和与关节面相关的并发症。采用健康调查简表 36(SF-36)评估健康相关生活质量(HRQL)。采用 X 线平片和计算机断层扫描(CT)进行影像学评估。
CoC 组和 CoXPE 组的 HHS 评分均有统计学意义的改善,两组之间无差异。在两组中,除了 CoC 组在总体健康维度上的评分明显较高(75.7 比 64.7,P=0.032)外,在最新随访时,两组之间的 SF-36 无显著差异。在最终随访时,均未发现影像学证据的骨溶解和松动。CoC 的平均磨损率为 0.0096mm/年,CoXPE 的磨损率为 0.047mm/年,通过重建 CT 进行评估。
CoC THA 与 CoXPE THA 治疗中期随访后股骨头坏死患者效果相当。CoC 关节面的磨损率明显低于 CoXPE 关节面。