Nickerson S C, Thompson W J, Oliver S P, Akers R M
Hill Farm Research Station, Louisiana State University Agricultural Center, Homer 71040.
Am J Vet Res. 1988 Aug;49(8):1205-9.
Effects of placing intracisternal bead devices (ICB) into teat cisterns of 6 dairy cows, from the end of lactation through parturition, were studied. Lacteal secretion samples were collected weekly from each mammary quarter during the nonlactating period to monitor composition changes in ICB-fitted and nonfitted quarters. In quarters remaining uninfected (n = 15), there were significantly higher mean somatic cell counts (P less than 0.05), percentage of neutrophils (P less than 0.019), and cell viability (P less than 0.038), but significantly lower percentage of macrophages (P less than 0.013) in ICB-fitted quarters compared with those in nonfitted quarters. The ICB had no significant effect on mean weekly values for percentage of lymphocytes, pH, lactoferrin, citrate, citrate/lactoferrin molar ratio, serum albumin, alpha-lactalbumin, and N-acetyl-beta-D-glucosaminidase. In infected quarters (n = 9), pH of mammary secretions was significantly (P less than 0.004) higher in ICB-fitted quarters, but concentrations of lactoferrin (P less than 0.004), alpha-lactalbumin (P less than 0.013), and N-acetyl-beta-D-glucosaminidase (P less than 0.028) were significantly lower, compared with those in nonfitted quarters. Coagulase-negative staphylococci comprised approximately 90% of all infections. Over the nonlactating period, 16.4 and 41.5% of samples from nonfitted and ICB-fitted quarters, respectively, contained coagulase-negative staphylococci. Microscopic examination of ICB from uninfected quarters revealed a thin coating of plaque with adhering neutrophils, macrophages, and multinucleated giant cells. Microscopic examination of plaque on devices from ICB-fitted quarters harboring coagulase-negative staphylococci revealed numerous adherent cocci and neutrophils.
研究了在6头奶牛的乳头池内放置脑池内珠装置(ICB)从泌乳期末到分娩期间的效果。在非泌乳期每周从每个乳腺象限采集乳汁分泌样本,以监测安装和未安装ICB的象限中的成分变化。在未感染的象限(n = 15)中,与未安装ICB的象限相比,安装ICB的象限中的平均体细胞计数显著更高(P < 0.05)、中性粒细胞百分比显著更高(P < 0.019)、细胞活力显著更高(P < 0.038),但巨噬细胞百分比显著更低(P < 0.013)。ICB对淋巴细胞百分比、pH、乳铁蛋白、柠檬酸盐、柠檬酸盐/乳铁蛋白摩尔比、血清白蛋白、α-乳白蛋白和N-乙酰-β-D-氨基葡萄糖苷酶的每周平均值没有显著影响。在感染的象限(n = 9)中,与未安装ICB的象限相比,安装ICB的象限中的乳腺分泌物pH显著更高(P < 0.004),但乳铁蛋白(P < 0.004)、α-乳白蛋白(P < 0.013)和N-乙酰-β-D-氨基葡萄糖苷酶(P < 0.028)的浓度显著更低。凝固酶阴性葡萄球菌约占所有感染的90%。在非泌乳期,未安装和安装ICB的象限的样本中分别有16.4%和41.5%含有凝固酶阴性葡萄球菌。对未感染象限的ICB进行显微镜检查发现有一层薄薄的斑块涂层,附着有中性粒细胞、巨噬细胞和多核巨细胞。对携带凝固酶阴性葡萄球菌的安装ICB的象限中的装置上的斑块进行显微镜检查发现有大量附着的球菌和中性粒细胞。