Suppr超能文献

比较不同动力学模型用于不同的、也包括双血输入函数的肝细胞癌动态 F-FDG PET/CT 成像。

Comparison of different kinetic models for dynamic F-FDG PET/CT imaging of hepatocellular carcinoma with various, also dual-blood input function.

机构信息

Division of Nuclear Medicine, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria. Both authors contributed equally to this work.

出版信息

Phys Med Biol. 2020 Feb 10;65(4):045001. doi: 10.1088/1361-6560/ab66e3.

Abstract

A kinetic modeling analysis was performed on hepatocellular carcinoma (HCC) as well as healthy liver tissue regions from dynamic FDG positron emission tomographys/computer tomography (PET/CT) cans. On basis of image derived input function from hepatic artery and portal vein, various kinetic models were compared among each other in order to check whether HCC can be classified and differ from healthy tissue within the kinetic parameters. 14 HCC and 10 healthy liver regions from FDG PET/CT scans of ten patients were analyzed from their time activity curves (TACs) were extracted from the PET dynamic images. Also the hepatic artery and the portal vein were delineated in the fused PET/CT images, which were used as input functions. Four kinetic models were applied to the TACs, using both or only one input function. Results were analyzed with several information criteria according to Akaike and Schwartz as well as be the F-Test. The paired student's t-test was used to determine the differences between HCC and healthy regions. All applied models revealed significant differences of p   <  0.01 of k between HCC and healthy liver and three out of four models produced almost identical values for k   =  0.03 min and K   =  0.03 min. According to the information criteria tests, a simple two-tissue model with only a venous input function is clearly preferred in case of HCC TACs. After dividing all HCC regions into two groups having a low and a high HCC-to-healthy ratio, respectively, this model also showed significant differences of k between these two groups. In conclusion, results indicate that the portal vein is sufficient to describe kinetic FDG processes in HCC and healthy liver regions.

摘要

对肝细胞癌 (HCC) 及动态 FDG 正电子发射断层扫描/计算机断层扫描 (PET/CT) 扫描的健康肝组织区域进行了动力学建模分析。基于肝动脉和门静脉的图像衍生输入函数,比较了不同的动力学模型,以检查 HCC 是否可以在动力学参数内进行分类并与健康组织区分开来。对 10 名患者的 FDG PET/CT 扫描中的 14 个 HCC 和 10 个健康肝区进行了分析,从 PET 动态图像中提取了它们的时间活动曲线 (TAC)。还在融合的 PET/CT 图像中描绘了肝动脉和门静脉,将其用作输入函数。将四种动力学模型应用于 TAC,使用一个或两个输入函数。根据 Akaike 和 Schwartz 的信息标准以及 F 检验对结果进行了分析。使用配对学生 t 检验确定 HCC 和健康区域之间的差异。所有应用的模型均显示 HCC 与健康肝之间的 k 差异具有统计学意义(p < 0.01),且四个模型中的三个产生了几乎相同的 k = 0.03 min 和 K = 0.03 min 值。根据信息标准测试,在 HCC TAC 的情况下,简单的双组织模型仅具有静脉输入函数是明显优选的。将所有 HCC 区域分为两组,分别具有低 HCC-健康比和高 HCC-健康比后,该模型在这两组之间的 k 差异也具有统计学意义。总之,结果表明门静脉足以描述 HCC 和健康肝区域中的动力学 FDG 过程。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验