Suppr超能文献

阑尾内留存铅弹患者的血铅水平。

Blood lead levels in patients with lead shot retained in the appendix.

作者信息

Madsen H H, Skjødt T, Jørgensen P J, Grandjean P

机构信息

Department of Diagnostic Radiology, Odense University Hospital, Denmark.

出版信息

Acta Radiol. 1988 Nov-Dec;29(6):745-6.

PMID:3190952
Abstract

Seven patients with one or two lead shots retained in the appendix were identified by radiography. For each case, two sex- and age-matched control patients without lead shot in the appendix were found. None of the 7 patients with lead shot in the appendix had blood lead levels (median 0.55 mumol/l) approaching the toxic levels, but they averaged almost twice the levels of the controls (median 0.29 mumol/l). Thus, lead shots may add to individual lead exposures, and blood lead analysis should be performed, at least when more than a few lead shots are present.

摘要

通过X光检查发现7例患者阑尾内留存有一枚或两枚铅弹。对于每例患者,均找到了两名年龄和性别匹配、阑尾内无铅弹的对照患者。7例阑尾内有铅弹的患者,其血铅水平(中位数为0.55微摩尔/升)均未接近中毒水平,但平均几乎是对照组(中位数为0.29微摩尔/升)的两倍。因此,铅弹可能会增加个体的铅暴露量,至少在存在多枚铅弹的情况下,应进行血铅分析。