Suppr超能文献

猫白线缝合闭合的最佳缝线咬口大小——一项尸体研究

Optimal Suture Bite Size for Closure of Feline Linea Alba-A Cadaveric Study.

作者信息

Bartier Amanda L, Atilla Aylin, Archer Rebecca, Kwong Grace P S

机构信息

Faculty of Veterinary Medicine, University of Calgary, Calgary, AB, Canada.

出版信息

Front Vet Sci. 2019 Dec 10;6:441. doi: 10.3389/fvets.2019.00441. eCollection 2019.

Abstract

This study aimed to determine the most appropriate suture bite and stitch interval (SBSI) size for closing feline linea alba. Randomized mechanical testing. Ventral abdominal walls from 35 male feline cadavers were harvested and separated into 125 segments. Segments were incised along midline then sutured back together using 3-0 polydioxanone using one of the following SBSI: 3, 5, 7.5, or 10 mm whereby the distance represents the distance both between the suture bites, and from the bite to incision line. The location of segments as well as the weight of the cadaver were recorded. A single linear distraction mechanical breaking test was performed. Statistical analyses (logistic and linear regression) were performed to determine which factors were associated with visual and mechanical failure, as well as load at failure or maximum displacement. SBSI was significantly associated with load at failure or maximum displacement ( < 0.001). In particular, 5 mm SBSI had the highest load at failure amongst all the bite sizes (LSmeans = 27.55N, 95% Confidence Interval (CI): 23.65-31.44); this was significantly higher than 7.5 mm (LSmeans = 19.15N, 95% CI: 15.26-23.05, = 0.016) and 10 mm (LSmeans = 16.55N, 95%CI:12.39-20.70, = 0.0012) but not significantly higher than 3 mm (LSmeans = 23.78N, 95% CI: 19.69-27.86, = 0.2). Increased SBSI increased the odds of visual failure ( < 0.001) whereas increased weight of the cadaver reduced the odds of visual failure (OR = 0.52, 95%CI: 0.30-0.88, = 0.016). The 5 mm SBSI had the highest load at failure and was not significantly different from the 3 mm SBSI when apposing feline linea alba using 3-0 polydioxanone. Using 5 mm SBSI is the preferred bite size compared to 7.5 or 10 mm SBSI when apposing feline linea alba with 3-0 polydioxanone.

摘要

本研究旨在确定用于闭合猫白线的最合适的缝合间距和针距(SBSI)尺寸。随机机械测试。采集35只雄性猫尸体的腹侧壁并分成125个节段。沿中线切开节段,然后使用3-0聚二氧六环酮以以下SBSI之一将其重新缝合在一起:3、5、7.5或10毫米,其中该距离代表缝合间距之间以及从间距到切口线的距离。记录节段的位置以及尸体的重量。进行单次线性牵张机械断裂测试。进行统计分析(逻辑回归和线性回归)以确定哪些因素与视觉和机械失败以及失败时的负荷或最大位移相关。SBSI与失败时的负荷或最大位移显著相关(<0.001)。特别是,5毫米SBSI在所有间距尺寸中失败时的负荷最高(最小二乘均值=27.55N,95%置信区间(CI):23.65-31.44);这显著高于7.5毫米(最小二乘均值=19.15N,95%CI:15.26-23.05,=0.016)和10毫米(最小二乘均值=16.55N,95%CI:12.39-20.70,=0.0012),但不显著高于3毫米(最小二乘均值=23.78N,95%CI:19.69-27.86,=0.2)。增加的SBSI增加了视觉失败的几率(<0.001),而尸体重量增加则降低了视觉失败的几率(OR=0.52,95%CI:0.30-0.88,=0.016)。当使用3-0聚二氧六环酮对猫白线进行缝合时,5毫米SBSI失败时的负荷最高,且与3毫米SBSI无显著差异。与7.5或10毫米SBSI相比,当使用3-0聚二氧六环酮对猫白线进行缝合时,使用5毫米SBSI是更优选的间距尺寸。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/590f/6914685/49de677a1ff3/fvets-06-00441-g0001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验