García-Hernández Trinitat, Vicedo-González Aurora, Sánchez-Nieto Beatriz, Romero-Expósito Maite, Roselló-Ferrando Joan
Departmento de Física Médica, ERESA Hospital General Universitario de Valencia, Valencia, Spain.
Instituto de Física, Pontificia Universidad Católica de Chile, Santiago, Chile.
Radiat Prot Dosimetry. 2020 Jun 24;188(3):285-298. doi: 10.1093/rpd/ncz286.
There is a growing interest in the use of flattening filter free (FFF) beams due to the shorter treatment times. The reduction of head scatter suggests a better radiation protection to radiotherapy patients, considering the expected decrease in peripheral surface dose (PSD). In this work, PSD of flattened (FF) and FFF-photon beams was compared. A radiochromic film calibration method to reduce energy dependence was used. PSD was measured at distances from 2 to 50 cm to the field border for different square field sizes, modifying relevant clinical parameters. Also, clinical breast and prostate stereotactic body radiotherapy (SBRT) plans were studied. For square beams, FFF PSD is lower compared with FF PSD (differences ranging from 3 to 64%) and 10 MV FFF yields to the lowest value, for distances greater than 5 cm. For SBRT plans, near and far away from the field border, there is a reduction of PSD for FFF-beams, but the behavior at intermediate distances should be checked depending on the case.
由于治疗时间更短,人们对无 flattening 滤波器(FFF)束流的使用兴趣日益浓厚。考虑到外周表面剂量(PSD)预期会降低,头部散射的减少表明对放疗患者有更好的辐射防护。在这项工作中,比较了 flattening(FF)光子束和 FFF 光子束的 PSD。使用了一种减少能量依赖性的放射变色胶片校准方法。针对不同的方形射野尺寸,在距射野边界 2 至 50 cm 的距离处测量 PSD,并修改相关临床参数。此外,还研究了临床乳腺和前列腺立体定向体部放射治疗(SBRT)计划。对于方形射野,对于大于 5 cm 的距离,FFF 的 PSD 低于 FF 的 PSD(差异范围为 3%至 64%),且 10 MV FFF 的 PSD 最低。对于 SBRT 计划,在靠近和远离射野边界处,FFF 束流的 PSD 会降低,但中间距离处的情况应根据具体病例进行检查。