Suppr超能文献

使用剪切波弹性成像评估喙肱韧带活动范围与弹性之间的相关性。

Correlations Between Range of Motion and Elasticity of the Coracohumeral Ligament Evaluated With Shear-Wave Elastography.

作者信息

Kanazawa Kenji, Hagiwara Yoshihiro, Sekiguchi Takuya, Fujita Ryo, Suzuki Kazuaki, Koide Masashi, Ando Akira, Yabe Yutaka

出版信息

J Sport Rehabil. 2020 Jan 24;30(1):9-15. doi: 10.1123/jsr.2019-0279.

Abstract

CONTEXT

Range of motion (ROM) in the glenohumeral joint decreases with age in healthy subjects; however, the underlying mechanism remains unclear. The process of aging of the joint capsule, including the coracohumeral ligament (CHL), could affect ROM limitation.

OBJECTIVE

This study investigated correlations between elasticity of the CHL, evaluated by means of shear-wave elastography, and age, side dominance, and ROM in healthy individuals.

DESIGN

Experimental study.

SETTING

Laboratory.

SUBJECTS

Eighty-four healthy volunteers (39 men and 45 women, mean age: 42.6 y) were included.

MAIN OUTCOME MEASURES

Subjects were divided into 3 age groups: younger (20-39 y), middle (40-59 y), and older (≥60 y) age groups. With participants in the supine position, CHL elasticity in both shoulders was evaluated in both neutral and 30° external rotation, with arms at the sides. ROM, including forward flexion, lateral elevation, external rotation, 90° abduction with external rotation, and hand behind the back were measured with participants in the standing position.

RESULTS

The CHL elastic modulus was higher in the older group than in the younger group in the neutral (78.4 kPa [SD: 37.1] and 56.6 kPa [SD: 31.7], respectively) and 30° external rotation positions (135.5 kPa [SD: 63.5] and 71.4 kPa [SD: 32.2], respectively). Negative correlations were found between the CHL elastic modulus and ROM in terms of 30° external rotation and both external rotation (R = -.59, P = .02) and 90° abduction with external rotation (R = -.71, P = .003) in the older group, with correlation coefficients increasing with age.

CONCLUSIONS

Significant correlations were identified between CHL elasticity and ROM in both external rotation and 90° abduction with external rotation with increasing age. Decreased CHL elasticity was strongly associated with decreased shoulder ROM in middle-aged and older individuals.

摘要

背景

在健康受试者中,盂肱关节的活动范围(ROM)会随着年龄增长而减小;然而,其潜在机制仍不清楚。关节囊的老化过程,包括喙肱韧带(CHL),可能会影响ROM受限情况。

目的

本研究调查了通过剪切波弹性成像评估的CHL弹性与健康个体的年龄、优势侧和ROM之间的相关性。

设计

实验研究。

地点

实验室。

受试者

纳入84名健康志愿者(39名男性和45名女性,平均年龄:42.6岁)。

主要观察指标

受试者分为3个年龄组:年轻组(20 - 39岁)、中年组(40 - 59岁)和老年组(≥60岁)。受试者仰卧位时,双臂置于身体两侧,在中立位和外旋30°时评估双肩的CHL弹性。受试者站立位时测量ROM,包括前屈、侧方抬高、外旋、外旋90°外展和手背后伸。

结果

老年组在中立位(分别为78.4 kPa [标准差:37.1]和56.6 kPa [标准差:31.7])和外旋30°位(分别为135.5 kPa [标准差:63.5]和71.4 kPa [标准差:32.2])的CHL弹性模量高于年轻组。老年组中,CHL弹性模量与外旋30°以及外旋(R = -0.59,P = 0.02)和外旋90°外展(R = -0.71,P = 0.003)时的ROM呈负相关,且相关系数随年龄增加。

结论

随着年龄增长,CHL弹性与外旋以及外旋90°外展时的ROM之间存在显著相关性。CHL弹性降低与中年和老年个体的肩部ROM减小密切相关。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验