Res Vet Sci. 2020 Apr;129:129-136. doi: 10.1016/j.rvsc.2020.01.014. Epub 2020 Jan 13.
The objectives of this prospective study were determination of reference intervals (RI) for rotational thromboelastometry (ROTEM) parameters in single use reagents and to evaluate correlations between plasmatic coagulation times and ROTEM parameters. Blood was sampled from a jugular vein in 49 client-owned healthy dogs and ex-tem S, in-tem S, fib-tem S and ap-tem S parameters, prothrombin time (PT), activated partial thromboplastin time (aPTT), fibrinogen, haematology, blood chemistry and venous blood gas analysis was performed. Determination of RI was performed using Excel add-in Reference Value Advisor and correlations between PT, aPTT and fibrinogen with selected ROTEM parameters were determined by Spearman correlation. Ex-tem S maximum clot firmness (MCF) RI are smaller compared to RI in people and liquid ex-tem in dogs while maximum lysis was comparable to those in people but smaller than previously reported in dogs. A strong correlation was found between fibrinogen measured by Clauss and fib-tem S and in-tem S MCF (r = 0.541, P < .001 and r = 0.610, P < .001, respectively). PT showed a significant but moderate correlation with ex-tem S CT (r = 0.340, P = .030), in-tem S CFT (r = 0.433, P = .003), fib-tem S CT (r = 0.426, P = .009) and ap-tem S CT (r = 0.354, P = .015) while aPTT was not significantly correlated with any of the evaluated parameters. In conclusion, this study provides single use reagent ROTEM parameter RIs that are different from RI determined with liquid reagents. Significant correlations between fibrinogen concentrations measured by Clauss and clot firmness of fib-tem S and in-tem S profiles and between PT and clotting times of all reagents were identified.
本前瞻性研究的目的是确定单次使用试剂旋转血栓弹性测定(ROTEM)参数的参考区间(RI),并评估血浆凝血时间与 ROTEM 参数之间的相关性。从 49 只患犬的颈静脉采集血液,检测 EXTEM、INTEM、FIBTEM 和 APTEM 参数、凝血酶原时间(PT)、活化部分凝血活酶时间(aPTT)、纤维蛋白原、血液学、血液化学和静脉血气分析。使用 Excel 插件参考值顾问确定 RI,通过 Spearman 相关性确定 PT、aPTT 和纤维蛋白原与选定 ROTEM 参数之间的相关性。EXTEM S 的最大凝块硬度(MCF)RI 与人和犬液体 EXTEM 的 RI 相比更小,而最大溶解与人和犬的报告相比更小。Clauss 法测量的纤维蛋白原与 FIBTEM S 和 INTEM S MCF 之间存在很强的相关性(r=0.541,P<0.001 和 r=0.610,P<0.001)。PT 与 EXTEM S CT(r=0.340,P=0.030)、INTEM S CFT(r=0.433,P=0.003)、FIBTEM S CT(r=0.426,P=0.009)和 APTEM S CT(r=0.354,P=0.015)呈显著但中度相关,而 aPTT 与评估的任何参数均无显著相关性。结论:本研究提供了单次使用试剂 ROTEM 参数 RI,与液体试剂确定的 RI 不同。Clauss 法测量的纤维蛋白原浓度与 FIBTEM S 和 INTEM S 图谱的凝块硬度之间,以及 PT 与所有试剂的凝血时间之间存在显著相关性。