Yung M W, Soliman A M
Department of Otorhinolaryngology, University of Liverpool.
J Laryngol Otol. 1988 Oct;102(10):861-4. doi: 10.1017/s0022215100106681.
Blockage of both jugular veins is often followed by signs of intracranial hypertension. The use of brainstem evoked responses (BSER) in the detection of brainstem compression following jugular vein ligation in guinea pigs was studied. Thirty pigmented guinea pigs were studied. Unilateral jugular vein ligation was performed in 10 animals and bilaterally in 10. Ten animals were controls. The BSER to clicks at 20 db above hearing thresholds before and 6 hours following ligation of one or both jugular veins were recorded. No change in the hearing threshold was observed following jugular vein(s) ligation. However, prolongation of the I-III and III-IV interpeak intervals were observed following both unilateral and bilateral jugular vein ligation. The results suggest that BSER monitoring may be useful in the early detection of brainstem compression following jugular vein ligation in head and neck surgery.
双侧颈静脉阻塞常伴有颅内高压的体征。研究了在豚鼠颈静脉结扎后使用脑干听觉诱发电位(BSER)检测脑干受压情况。对30只有色豚鼠进行了研究。10只动物进行了单侧颈静脉结扎,10只进行了双侧颈静脉结扎。10只动物作为对照。记录了在结扎一侧或双侧颈静脉之前以及结扎后6小时,在高于听阈20分贝时对点击声的BSER。颈静脉结扎后未观察到听阈变化。然而,单侧和双侧颈静脉结扎后均观察到I-III和III-IV峰间期延长。结果表明,BSER监测可能有助于在头颈外科手术中颈静脉结扎后早期检测脑干受压情况。