Er İlkay, Günlemez Ayla, Baydemir Canan, Kılıçbay Fatih, Ersu Refika, Uyan Zeynep Seda
Divisions of Neonatology, Kocaeli University Faculty of Medicine, Kocaeli, Turkey.
Department of Biostatistics and Medical Informatics, Kocaeli University Faculty of Medicine, Kocaeli, Turkey.
Turk J Pediatr. 2019;61(4):560-567. doi: 10.24953/turkjped.2019.04.013.
Er İ, Günlemez A, Baydemir C, Kılıçbay F, Ersu R, Uyan ZS. Impulse oscillometry reference values and correlation with predictors in Turkish preschool children. Turk J Pediatr 2019; 61: 560-567. Impulse oscillometry (IOS) is a noninvasive, rapid technique requiring passive cooperation that allows for evaluation of lung function through the measurement of airway resistance and reactance. There are no available reference values for Turkish children. This study is aimed to determine the reference values of IOS parameters and to study their correlation with height, weight, body mass index, and age as predictors in healthy Turkish preschool children. Healthy children between 3-7 years of age who were selected according to ERS/ATS criteria and followed at Kocaeli University outpatient clinic performed IOS. The correlation between the anthropometric predictor variables and resistance and reactance at 5-20 hertz (R5-R20 and X5-X20), the respiratory impedance at 5 hertz (Z5), resistance area (AX) and resonance frequency (Fres) were assessed by regression analysis and stepwise method. 151 children (93 female) with the mean age of 67.9±16.2 months participated in the study. Multilinear regression analysis for IOS values of all children revealed that resistance was significantly correlated with height and reactance was significantly correlated with age (p < 0.05). For girls, height had a negative effect on R5-20, Z5, AX values, while age had a positive effect on X5-20 and a negative effect on Fres (p < 0.05). For boys, weight had a negative effect on R5- 20, Z5 values, while age had a positive effect on X15-20 and a negative effect on AX, Fres (p < 0,05). This study provided reference values of IOS in healthy Turkish children that would be a useful guide for diagnosing and following respiratory diseases in preschool children.
埃尔·伊、居内勒梅兹·A、巴伊德米尔·C、基利奇贝伊·F、埃尔苏·R、于扬·ZS。土耳其学龄前儿童的脉冲振荡法参考值及其与预测指标的相关性。《土耳其儿科学杂志》2019年;61:560 - 567。脉冲振荡法(IOS)是一种无创、快速的技术,只需被动配合,通过测量气道阻力和电抗来评估肺功能。目前尚无土耳其儿童的可用参考值。本研究旨在确定IOS参数的参考值,并研究其与健康土耳其学龄前儿童的身高、体重、体重指数和年龄等预测指标的相关性。根据欧洲呼吸学会/美国胸科学会标准选取并在科贾埃利大学门诊随访的3至7岁健康儿童进行了IOS检查。通过回归分析和逐步法评估人体测量预测变量与5至20赫兹时的阻力和电抗(R5 - R20和X5 - X20)、5赫兹时的呼吸阻抗(Z5)、阻力面积(AX)和共振频率(Fres)之间的相关性。151名儿童(93名女性)参与了该研究,平均年龄为67.9±16.2个月。对所有儿童的IOS值进行多线性回归分析显示,阻力与身高显著相关,电抗与年龄显著相关(p < 0.05)。对于女孩,身高对R5 - 20、Z5、AX值有负面影响,而年龄对X5 - 20有正面影响,对Fres有负面影响(p < 0.05)。对于男孩,体重对R5 - 20、Z5值有负面影响,而年龄对X15 - 20有正面影响,对AX、Fres有负面影响(p < 0.05)。本研究提供了健康土耳其儿童的IOS参考值,这将为学龄前儿童呼吸系统疾病的诊断和随访提供有用的指导。