Suppr超能文献

脉冲震荡系统对囊性纤维化患者的评估和随访是否有用?

Is Impulse Oscillometry System a Useful Method for the Evaluation and Follow-Up of Patients with Cystic Fibrosis?

机构信息

Division of Pulmonology, Department of Pediatrics, Ege University Faculty of Medicine, İzmir, Turkey.

出版信息

Pediatr Allergy Immunol Pulmonol. 2021 Mar;34(1):15-22. doi: 10.1089/ped.2020.1317.

Abstract

Although the impulse oscillometry system (IOS) is a noninvasive, easily accessible, well-tolerated, and alternative test, routine use of IOS in cystic fibrosis (CF) patients is not widespread. In our unit, IOS is routinely used for the evaluation and follow-up of patients with CF. We aimed to show that IOS may be utilized as a complement for measuring pulmonary function in CF patients. Retrospective data collection and analysis of pulmonary function tests on CF patients followed at our center between January 1, 2018 and February 1, 2019. IOS and spirometry data were compared as correlated with patients' clinical exacerbation, treatment response, bronchodilator response, and trends during follow-up intervals. There was a significant correlation between spirometry and IOS parameters in 70 patients. In exacerbation, Z5, R5-R10, AX, Fres, and delta R5-R20 were significantly increased and X5-X20 was significantly decreased compared with baseline in 25 patients. After treatment, IOS parameters were observed to return to baseline values. In the evaluation of bronchodilator response in 33 patients, significant changes in IOS (decrease in Z5, R5-R10, AX, Fres, and delta R5-R20, and increase in X5-X10) and in spirometry [increase in forced expiratory volume in 1 s (FEV1) and forced expiratory flow during the middle half of forced vital capacity (FEF)] were found after bronchodilator. While there was no significant difference between spirometry values in follow-up visits in 31 patients, there was a significant increase in Z5% and R5%-R20%. Unlike other studies, there was a significant correlation between clinical scores and IOS. These results show that although IOS is not the gold standard method such as spirometry, it is an alternative method that can be used successfully in the evaluation and follow-up of CF patients. Clinical Trials.gov ID: 99166796-050.06.04.

摘要

尽管脉冲震荡系统(IOS)是一种非侵入性、易于获得、耐受性良好的替代测试方法,但在囊性纤维化(CF)患者中常规使用 IOS 并不广泛。在我们的单位,IOS 被常规用于评估和随访 CF 患者。我们旨在表明 IOS 可用于 CF 患者的肺功能测量。

回顾性收集和分析 2018 年 1 月 1 日至 2019 年 2 月 1 日在我们中心随访的 CF 患者的肺功能测试数据。将 IOS 和肺活量计数据与患者的临床恶化、治疗反应、支气管扩张剂反应以及随访期间的趋势进行相关性比较。

在 70 例患者中,IOS 和肺活量计参数之间存在显著相关性。在 25 例患者中,与基线相比,在恶化时,Z5、R5-R10、AX、Fres 和 delta R5-R20 显著增加,而 X5-X20 显著降低。在治疗后,IOS 参数观察到恢复到基线值。在 33 例患者的支气管扩张剂反应评估中,IOS(Z5、R5-R10、AX、Fres 和 delta R5-R20 减少,X5-X10 增加)和肺活量计(用力呼气量在 1 秒内增加(FEV1)和用力肺活量中间一半的呼气流量(FEF))有显著变化。在 31 例患者的随访中,肺活量计值无显著差异,但 Z5%和 R5%-R20%显著增加。与其他研究不同,IOS 与临床评分之间存在显著相关性。

这些结果表明,尽管 IOS 不是像肺活量计那样的金标准方法,但它是一种可成功用于 CF 患者评估和随访的替代方法。临床试验.gov ID:99166796-050.06.04。

相似文献

7
Application Value of Broadband 3-Dimensional Impulse Oscillometry in COPD.宽带三维脉冲震荡技术在 COPD 中的应用价值。
Int J Chron Obstruct Pulmon Dis. 2021 Feb 4;16:215-223. doi: 10.2147/COPD.S285927. eCollection 2021.

本文引用的文献

10
Impulse oscillometry in the evaluation of diseases of the airways in children.脉冲振荡法在儿童气道疾病评估中的应用。
Ann Allergy Asthma Immunol. 2011 Mar;106(3):191-9. doi: 10.1016/j.anai.2010.11.011. Epub 2011 Jan 6.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验