Suppr超能文献

两种改良两点辨别试验和两点估计触觉敏锐度试验的可靠性和效率比较。

Comparison of reliability and efficiency of two modified two-point discrimination tests and two-point estimation tactile acuity test.

机构信息

Department of Physical Therapy, University of South Dakota, Vermillion, SD, USA.

出版信息

Physiother Theory Pract. 2022 Jan;38(1):235-244. doi: 10.1080/09593985.2020.1719563. Epub 2020 Jan 29.

Abstract

: Determine reliability and minimal detectible difference of two modified two-point discrimination (TPD) testing methods and explore reliability of newer tactile acuity test, two-point estimation (TPE) method.: Non-experimental observational reliability study.: Community.: Thirty-five (female = 25) healthy individuals average age 27.7 years (SD = 9.7).: Two modified methods (i.e., descending-ascending and descending with randomization) of TPD testing utilizing decreased runs of descending and ascending measurements were tested for inter-rater reliability and efficiency between two testers at three locations (neck, hand, and foot). The newer tactile acuity test of TPE was also performed between both examiners at the three location sites.: Inter-rater reliability (ICC 2, ) for the descending-ascending method was 0.75, 0.79, and 0.67 for the neck, hand, and foot, respectively. For the descending with randomization method, ICC values were 0.74, 0.50, and 0.69 for the three body regions respectively. The minimal detectable difference for the neck was 28.8 and 32.7 mm, hand 5.3 and 10.8 mm, and foot 12.3 and 12.4 mm for the descending-ascending and randomization methods. TPE showed poor reliability for neck and hand (0.27 and 0.15), but moderate reliability for the foot (0.67). Time to perform the TPD test were between 54 and 108 seconds, while TPE was 12 seconds.: The modified TPD testing methods demonstrated similar reliability to previous research, even with reduced runs allowing for increased efficiency in performing the test. The TPE method showed poor reliability, so caution should be applied when using this method.

摘要

: 确定两种改良的两点辨别测试(TPD)方法的可靠性和最小可检测差异,并探讨新的触觉敏锐度测试——两点估计(TPE)方法的可靠性。: 非实验性观察可靠性研究。: 社区。: 35 名(女性=25 名)健康个体,平均年龄 27.7 岁(SD=9.7)。: 对三种部位(颈部、手部和足部)进行了两种改良的 TPD 测试方法(即递减递增和递减随机)的测试,评估了两名测试者之间的组内可靠性和效率。还在三个部位(颈部、手部和足部)对两名检查者进行了新的 TPE 触觉敏锐度测试。: 递减递增方法的组内可靠性(ICC 2, )分别为颈部 0.75、手部 0.79 和足部 0.67。对于递减随机方法,三个身体部位的 ICC 值分别为 0.74、0.50 和 0.69。颈部的最小可检测差异为 28.8 和 32.7mm,手部为 5.3 和 10.8mm,足部为 12.3 和 12.4mm,分别用于递减递增和随机方法。TPE 对颈部和手部的可靠性较差(0.27 和 0.15),但对足部的可靠性为中度(0.67)。执行 TPD 测试的时间在 54 到 108 秒之间,而 TPE 只需 12 秒。: 改良的 TPD 测试方法显示出与先前研究相似的可靠性,即使减少了测试的运行次数,也提高了测试效率。TPE 方法的可靠性较差,因此在使用该方法时应谨慎。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验