Menezes Julia Miranda, Rossener Raissa, Silva Ana Paula Marques Aguirra da, Rodrigues Silvia Sanches, Mangueira Cristóvão Luis Pitangueira
Faculdade Israelita de Ciências da Saúde Albert Einstein, Hospital Israelita Albert Einstein, São Paulo, SP, Brazil.
Hospital Israelita Albert Einstein, São Paulo, SP, Brazil.
Einstein (Sao Paulo). 2020 Jan 27;18:eAO5132. doi: 10.31744/einstein_journal/2020AO5132. eCollection 2020.
To evaluate the performance of enzyme-linked immunosorbent assay and indirect immunofluorescence methods for the detection of antineutrophil cytoplasmic antibodies in a routine clinical laboratory setting.
A total of 227 samples were tested by indirect immunofluorescence and enzyme-linked immunosorbent assay with antigen specificity for antiproteinase 3 and antimyeloperoxidase. The proportions of positive samples were compared by McNemar hypotheses and agreement was described by Cohen's Kappa coefficient.
The agreement of the tests was 96.5%, and the Kappa coefficient obtained was 0.70 (95%CI: 0.50-0.90; p<0.001). Considering indirect immunofluorescence as the gold standard, the sensitivity of the enzyme-linked immunosorbent assay was 0.62 and the specificity was 0.99, with diagnostic accuracy in 96% of cases. Some samples were negative in enzyme-linked immunosorbent assay and positive in indirect immunofluorescence. This situation occurred in all immunofluorescence patterns, but particularly in atypical patterns. Two samples with antiproteinase 3 positivity were considered negative in indirect immunofluorescence.
The enzyme-linked immunosorbent assay had high specificity but lower sensitivity. The performance of indirect immunofluorescence increases diagnostic sensitivity, while the search for antiproteinase 3 by enzyme-linked immunosorbent assay may also add diagnostic power.
在常规临床实验室环境中评估酶联免疫吸附测定法和间接免疫荧光法检测抗中性粒细胞胞浆抗体的性能。
采用间接免疫荧光法和酶联免疫吸附测定法对227份样本进行抗蛋白酶3和抗髓过氧化物酶抗原特异性检测。通过McNemar假设比较阳性样本比例,并用Cohen's Kappa系数描述一致性。
检测的一致性为96.5%,获得的Kappa系数为0.70(95%CI:0.50 - 0.90;p<0.001)。以间接免疫荧光法为金标准,酶联免疫吸附测定法的敏感性为0.62,特异性为0.99,诊断准确率为96%。一些样本在酶联免疫吸附测定法中为阴性,而在间接免疫荧光法中为阳性。这种情况在所有免疫荧光模式中均有发生,但在非典型模式中尤为明显。两份抗蛋白酶3阳性样本在间接免疫荧光法中被判定为阴性。
酶联免疫吸附测定法具有高特异性但敏感性较低。间接免疫荧光法的性能提高了诊断敏感性,而通过酶联免疫吸附测定法检测抗蛋白酶3也可能增加诊断效能。