Paul J M, Koch R F, Philip P C
Northwest Community Hospital, Arlington Heights, Illinois 60005.
Radiother Oncol. 1988 Oct;13(2):105-25. doi: 10.1016/0167-8140(88)90032-1.
In brachytherapy, articles are published with dose and homogeneity specifications using different systems which are hard to compare. For the same "stated dose", the dose delivered, volume treated and activity chosen are not the same in different systems, due to the fact that the source placement rules are different. In this article, the authors have circumvented this problem by the use of an approach not applied hitherto, viz. by determining the value of the Uniformity index (UI) of an implant using different systems. This value takes into account the integral dose within the treatment volume and is compared with an idealized implant, where the dose is uniform and the target and treatment volumes are the same. This method of evaluation has been applied for single plane, multiple plane and cylindrical volume implants using the Manchester, Quimby and Paris systems. Although the results obtained are different, the degree of closeness of these values are striking, with some minor exceptions. Thus, it is possible to combine all the brachytherapy parameters, such as: dose, homogeneity, treatment volume within a single value to determine the quality of an implant.
在近距离放射治疗中,发表的文章使用不同的系统给出剂量和均匀性规格,这些系统很难进行比较。对于相同的“规定剂量”,由于源放置规则不同,不同系统中输送的剂量、治疗的体积和选择的活度并不相同。在本文中,作者通过使用一种迄今未应用的方法规避了这个问题,即通过确定使用不同系统的植入物的均匀性指数(UI)值。该值考虑了治疗体积内的积分剂量,并与理想化的植入物进行比较,在理想化植入物中剂量是均匀的,靶区和治疗体积相同。这种评估方法已应用于使用曼彻斯特、昆比和巴黎系统的单平面、多平面和圆柱形体积植入物。尽管获得的结果不同,但这些值的接近程度令人惊讶,只有一些小的例外。因此,有可能将所有近距离放射治疗参数,如剂量、均匀性、治疗体积合并为一个单一值,以确定植入物的质量。