Suppr超能文献

使用局部造影剂给药对咽鼓管进行CT成像:一项人体可行性研究。

CT imaging of the Eustachian tube using focal contrast medium administration: a feasibility study in humans.

作者信息

Falkenberg-Jensen Benedicte, Jablonski Greg E, Silvola Juha T, Kristiansen Joanna F, Hopp Einar

机构信息

Division of Radiology and Nuclear Medicine, Rikshospitalet, Oslo University Hospital, Oslo, Norway.

Faculty of Medicine, Oslo University, Oslo, Norway.

出版信息

Acta Radiol Open. 2020 Jan 22;9(1):2058460119900435. doi: 10.1177/2058460119900435. eCollection 2020 Jan.

Abstract

Several methods of imaging the Eustachian tube have been tested in the last century, although neither has led to an established method. The introduction of balloon Eustachian tuboplasty (BET) has revived the request for Eustachian tube (ET) visualization in patients with chronic Eustachian tube dysfunction. Many institutions perform preoperative computed tomography (CT) scans of the temporal bone and epipharynx before BET. We hypothesize that the injection of a contrast medium into the tympanic cavity is safe and feasible and can evolve the CT scan by visualizing the ET lumen and, potentially, the level of obstruction. This study is the initial feasibility study for such a human application. Ten minutes before a CT scan, diluted iodixanol was injected into the middle ear in 18 patients planned for BET due to otitis media with effusion. Five patients with Meniere's disease were controls. Any immediate or delayed adverse events were recorded. Masking of adjacent bony structures in the middle ear on the CT images was evaluated and the most caudally visible contrast medium between the middle ear and epipharynx recorded. There were no serious adverse events. One patient reported transitory vertigo. The contrast medium did not mask middle ear structures, apart from the tympanic membrane. The level of contrast medium passage could be assessed. Visualizing the ET lumen in humans using intratympanic contrast medium is feasible and safe and does not obscure other valuable image information in a preoperative CT scan.

摘要

在上个世纪,已经对几种咽鼓管成像方法进行了测试,尽管都没有形成一种既定的方法。球囊咽鼓管成形术(BET)的引入,再次引发了对慢性咽鼓管功能障碍患者进行咽鼓管(ET)可视化检查的需求。许多机构在进行BET之前,会对颞骨和鼻咽部进行术前计算机断层扫描(CT)。我们假设向鼓腔注射造影剂是安全可行的,并且可以通过显示咽鼓管管腔以及潜在的阻塞水平来改进CT扫描。本研究是针对这种人体应用的初步可行性研究。在对18例因中耳积液计划进行BET的患者进行CT扫描前10分钟,将稀释的碘克沙醇注入中耳。5例梅尼埃病患者作为对照。记录任何即时或延迟的不良事件。评估CT图像上中耳相邻骨质结构的遮蔽情况,并记录中耳与鼻咽部之间最靠尾端可见的造影剂。未发生严重不良事件。1例患者报告有短暂眩晕。除鼓膜外,造影剂未遮蔽中耳结构。可以评估造影剂通过的水平。使用鼓室内造影剂在人体中显示咽鼓管管腔是可行且安全的,并且不会在术前CT扫描中掩盖其他有价值的图像信息。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/4067/6977099/711a7b3e9051/10.1177_2058460119900435-fig1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验