一种新的“实用”咽鼓管测量仪及其在预测后天性胆脂瘤患者中耳功能障碍中的应用。

A new "practical" plane for Eustachian tube measurements and its application in predicting middle ear dysfunction in patient with acquired cholesteatomas.

机构信息

Department of Otolaryngology, The Royal Victorian Eye and Ear Hospital, 32 Gisborne St, East Melbourne, VIC, 3002, Australia.

Department of Radiology, John Hunter Hospital, Newcastle, Australia.

出版信息

Eur Arch Otorhinolaryngol. 2022 Oct;279(10):4917-4923. doi: 10.1007/s00405-022-07345-3. Epub 2022 Mar 31.

Abstract

SETTING

The Eustachian tube plays a vital role in middle ear physiology. There has been evidence that Eustachian tube (ET) and angle are correlated with middle ear function. The measurements of these Eustachian tube features are now made possible with computed tomography and multiplanar reconstruction techniques. However, there has not been a standardised protocol devised to these measurements in limited window cone-beam CT scans of temporal bones.

OBJECTIVE

The primary object of the present study is to establish and validate a new landmark in closer proximity to the middle ear that is consistently captured, thereby allowing ET angle and length to be measured from the majority of cone-beam CT scans. Secondarily, the ET anatomies of patients with middle ear dysfunction manifesting as acquired cholesteatoma are analysed with this new method of measurement.

METHODS

This study undertook a step-by-step method to first validate the methods of ET measurement with Reid's standard plane, then identifying an alternative landmark, thus a new plane visible on limited window cone-beam CT scans of temporal bones and lastly, validating the application of this new plane in the measurements of ET angle and length. This new method of measurement was coined the Ku-Copson plane and was applied to 30 cochlear implant patients and 30 patients with acquired cholesteatomas. Their ET anatomies were analysed and compared.

RESULTS

It was found that the new Ku-Copson mandibular fossa plane was a reliable and accurate plane for the measurement of ET angle and length. Furthermore, it was found that patients with acquired cholesteatomas have statistically significant smaller ET angles and shorter ET lengths when compared with patients with cochlear implants, of normal middle ear function.

CONCLUSION

The newly proposed method utilising the right mandibular fossa as an anatomical landmark for ET angles and lengths measurement appears to be viable. The close proximity of this landmark to the middle ear means that it is highly likely to be captured in most cone-beam CT scans of the petrous temporal bones. This enables the retrospective examination ET angles and lengths to be conducted on CB CT scans. This study reports statistically significant difference in ET anatomy in patients with middle ear dysfunction.

摘要

背景

咽鼓管在中耳生理学中起着至关重要的作用。有证据表明,咽鼓管(ET)和角度与中耳功能相关。现在,使用计算机断层扫描和多平面重建技术可以对这些咽鼓管特征进行测量。然而,在有限的锥形束 CT 颞骨扫描中,尚未制定出这些测量的标准化方案。

目的

本研究的主要目的是建立并验证一种更接近中耳的新标志,以便能够从大多数锥形束 CT 扫描中测量 ET 角度和长度。其次,通过这种新的测量方法分析表现为获得性胆脂瘤的中耳功能障碍患者的 ET 解剖结构。

方法

本研究采用逐步方法,首先使用 Reid 标准平面验证 ET 测量方法,然后确定替代标志,从而在有限的锥形束 CT 颞骨扫描中可以看到一个新的平面,最后验证该新平面在 ET 角度和长度测量中的应用。这种新的测量方法被称为 Ku-Copson 平面,并应用于 30 例人工耳蜗植入患者和 30 例获得性胆脂瘤患者。分析并比较他们的 ET 解剖结构。

结果

研究发现,新的 Ku-Copson 下颌窝平面是测量 ET 角度和长度的可靠且准确的平面。此外,与具有正常中耳功能的人工耳蜗植入患者相比,患有获得性胆脂瘤的患者的 ET 角度和 ET 长度明显较小。

结论

利用右侧下颌窝作为 ET 角度和长度测量的解剖学标志的新方法似乎是可行的。该标志与中耳的接近程度意味着它很可能在大多数锥形束 CT 扫描的岩骨颞骨中被捕获。这使得可以在 CB CT 扫描上进行 ET 角度和长度的回顾性检查。本研究报告了中耳功能障碍患者的 ET 解剖结构存在统计学显著差异。