Toxalim (Research Centre in Food Toxicology), Toulouse University, INRAE, ENVT, INP-Purpan, UPS, F-31027 Toulouse, France; Metatoul-Axiom Platform, MetaboHUB, National Infrastructure for Metabolomics and Fluxomics, Toxalim, INRAE, F-31027 Toulouse, France.
Food Chem. 2020 Jun 30;316:126327. doi: 10.1016/j.foodchem.2020.126327. Epub 2020 Jan 30.
Heterocyclic aromatic amines (HAAs) are neo-formed compounds generated during the cooking of meats and are known or suspected to be mutagenic and carcinogenic. In this study, a novel, simple, and fast methodology combining salting-out liquid-liquid microextraction, solid-phase extraction (SPE), and UHPLC-APCI-MS/MS was developed for the analysis of 16 HAAs. The QuEChERS extraction (quick, easy, cheap, efficient, rugged, and safe) was revisited and modified using mixed-mode SPE purification to adapt the method to the particular physicochemical properties of HAAs and the fatty nature of the beef matrix. The UHPLC-MS/MS analysis was performed on a C8 column in less than 4 min using positive APCI ionisation and an internal standard. The method was validated according to the European Medicines Agency and Eurachem guidelines and was successfully applied to beef samples of various cooking degrees, showing HAA levels similar to those shown by previous studies.
杂环胺(HAAs)是在肉类烹饪过程中形成的新型化合物,已知或怀疑其具有致突变性和致癌性。在这项研究中,开发了一种新颖、简单、快速的方法,结合盐析液-液微萃取、固相萃取(SPE)和 UHPLC-APCI-MS/MS 分析 16 种杂环胺。QuEChERS 提取(快速、简单、廉价、有效、坚固耐用和安全)经过重新审视和修改,使用混合模式 SPE 净化以适应方法对 HAAs 的特殊物理化学性质和牛肉基质的脂肪性质。UHPLC-MS/MS 分析在 C8 柱上进行,不到 4 分钟即可完成,采用正 APCI 离子化和内标法。该方法根据欧洲药品管理局和 Eurachem 指南进行了验证,并成功应用于各种烹饪程度的牛肉样品,显示出与先前研究相似的 HAA 水平。