Evaluation of the performance of an endoscopic 3-mm electrothermal bipolar vessel sealing device intended for single use after multiple use-and-resterilization cycles.

作者信息

Quitzan Juliany Gomes, Singh Ameet, Beaufrere Hugues, Valverde Alexander, Lillie Brandon, Salahshoor Masoomeh, Bardelcik Alexander, Saleh Tarek M

机构信息

School of Veterinary Medicine and Animal Science, Sao Paulo State University, Botucatu, Sao Paulo, Brazil.

Department of Clinical Studies, Ontario Veterinary College, University of Guelph, Ontario, Canada.

出版信息

Vet Surg. 2020 Jun;49 Suppl 1:O120-O130. doi: 10.1111/vsu.13396. Epub 2020 Feb 13.

DOI:10.1111/vsu.13396
PMID:32053219
Abstract

OBJECTIVE

To evaluate the performance of an endoscopic 3-mm electrothermal bipolar vessel sealing device (EBVS) intended for single use after multiple use-and-resterilization cycles.

STUDY DESIGN

Ex vivo study.

SAMPLE POPULATION

Eight 3-mm EBVS handpieces.

METHODS

Handpieces were subjected to a maximum of 15 cycles of testing, including simulated surgery, sealing and burst pressure testing of porcine carotid arteries, reprocessing, and hydrogen peroxide plasma resterilization. Failure was defined as two sequential vascular seal leakage events occurring at <250 mm Hg. Histological evaluation, maximum external temperature of the jaws, sealing time, tissue adherence, jaw surface characterization, and mechanical deterioration were studied. Failure rate was analyzed by using a Kaplan-Meier curve. Linear and ordinal logistic mixed models were used to analyze sealing time, handpiece jaw temperature, and adherence score.

RESULTS

Mean ± SD diameter of arteries was 3.22 ± 0.35 mm. Failure was observed starting at cycle 10 and going up to cycle 13 in 37.5% (3/8) of the handpieces. Tissue adherence increased after each cycle (P < .001). Maximum external temperature (79.8°C ± 13.9°C) and sealing time (1.8 ± 0.5 seconds) were not significantly different throughout cycles up to failure. A flatter surface and large scratches were observed microscopically throughout the jaw surface after repeated use and resterilization.

CONCLUSION

The 3-mm EBVS handpiece evaluated in this study can be considered safe to use for up to nine reuse-and-resterilization cycles.

CLINICAL SIGNIFICANCE

These data provide the basis for establishing preliminary guidelines for the reuse and hydrogen peroxide plasma resterilization of an endoscopic 3-mm EBVS handpiece.

摘要

相似文献

1
Evaluation of the performance of an endoscopic 3-mm electrothermal bipolar vessel sealing device intended for single use after multiple use-and-resterilization cycles.
Vet Surg. 2020 Jun;49 Suppl 1:O120-O130. doi: 10.1111/vsu.13396. Epub 2020 Feb 13.
2
Influence of multiple reuse and resterilization cycles on the performance of a bipolar vessel sealing device (LigaSure) intended for single use.
Vet Surg. 2018 Oct;47(7):951-957. doi: 10.1111/vsu.12948. Epub 2018 Sep 4.
3
Performance and microbiological safety testing after multiple use cycles and hydrogen peroxide sterilization of a 5-mm vessel-sealing device.
Vet Surg. 2019 Jul;48(5):885-889. doi: 10.1111/vsu.13191. Epub 2019 Mar 18.
4
Carotid artery bursting pressure and seal time after multiple uses of a vessel sealing device.血管封闭装置多次使用后的颈动脉破裂压力和封闭时间。
Vet Surg. 2017 May;46(4):501-506. doi: 10.1111/vsu.12648. Epub 2017 Mar 23.
5
Effect of multiple use and sterilization on sealing performance of bipolar vessel sealing devices.多次使用和消毒对双极血管密封设备密封性能的影响。
PLoS One. 2019 Aug 20;14(8):e0221488. doi: 10.1371/journal.pone.0221488. eCollection 2019.
6
Evaluation of the efficacy of the electrosurgical bipolar vessel sealer (LigaSure) devices in sealing lymphatic vessels.评估电外科双极血管闭合器(LigaSure)设备闭合淋巴管的疗效。
Surg Innov. 2005 Jun;12(2):155-60. doi: 10.1177/155335060501200215.
7
Bipolar vessel sealing: instrument contamination and wear have little effect on seal quality and success in a porcine in vitro model.双极血管封闭:在猪体外模型中,器械污染和磨损对封闭质量及成功率影响甚微。
Langenbecks Arch Surg. 2014 Oct;399(7):863-71. doi: 10.1007/s00423-014-1234-2. Epub 2014 Jul 27.
8
Differential response of arteries and veins to bipolar vessel sealing: evaluation of a novel reusable device.动脉和静脉对双极血管封闭的不同反应:一种新型可重复使用装置的评估
J Laparoendosc Adv Surg Tech A. 2006 Apr;16(2):149-55. doi: 10.1089/lap.2006.16.149.
9
Comparison of linear and torsional mode ultrasonic coagulating shears for the sealing of medium- to large-sized arteries.用于中大型动脉封闭的线性模式与扭转模式超声凝固剪的比较。
Surg Endosc. 2007 Jul;21(7):1165-9. doi: 10.1007/s00464-006-9113-8. Epub 2006 Dec 6.
10
Effectiveness of the ultrasonic coagulating shears, LigaSure vessel sealer, and surgical clip application in biliary surgery: a comparative analysis.超声凝固剪、LigaSure血管闭合器及手术夹在胆道手术中的应用效果:一项对比分析。
Am Surg. 2001 Sep;67(9):901-6.