Suppr超能文献

双能计算机断层扫描中颈部、腋窝和腹股沟健康淋巴结的碘浓度

Iodine concentration of healthy lymph nodes of neck, axilla, and groin in dual-energy computed tomography.

作者信息

Sauter Andreas P, Ostmeier Sophie, Nadjiri Jonathan, Deniffel Dominik, Rummeny Ernst J, Pfeiffer Daniela

机构信息

9184Technical University of Munich, School of Medicine, Klinikum rechts der Isar, Department of Diagnostic and Interventional Radiology, Munich, Germany.

出版信息

Acta Radiol. 2020 Nov;61(11):1505-1511. doi: 10.1177/0284185120903448. Epub 2020 Feb 16.

Abstract

BACKGROUND

Lymph nodes (LN) are examined in every computed tomography (CT) scan. Until now, an evaluation is only possible based on morphological criteria. With dual-energy CT (DECT) systems, iodine concentration (IC) can be measured which could conduct in an improved diagnostic evaluation of LNs.

PURPOSE

To define standard values for IC of cervical, axillary, and inguinal LNs in DECT.

MATERIAL AND METHODS

Imaging data of 297 patients who received a DECT scan of the neck, thorax, abdomen-pelvis, or a combination of those in a portal-venous phase were retrospectively collected from the institutional PACS. No present history of malignancy, inflammation, or trauma in the examined region was present. For each examined region, the data of 99 patients were used. The IC of the three largest LNs, the main artery, the main vein, and a local muscle of the examined area was measured, respectively.

RESULTS

Normalization of the IC of LNs to the artery, vein, muscle, or a combination of those did not lead to a decreased value-range. The smallest range and confidence interval (CI) of IC was found when using absolute values of IC for each region. Hereby, mean values (95% CI) for IC of LN were found: 2.09 mg/mL (2.00-2.18 mg/mL) for neck, 1.24 mg/mL (1.16-1.33 mg/mL) for axilla, and 1.11 mg/mL (1.04-1.17 mg/mL) for groin.

CONCLUSION

The present study suggests standard values for IC of LNs in dual-layer CT could be used to differentiate between healthy and pathological lymph nodes, considering the used contrast injection protocol.

摘要

背景

在每次计算机断层扫描(CT)中都会检查淋巴结(LN)。到目前为止,评估仅基于形态学标准。使用双能CT(DECT)系统,可以测量碘浓度(IC),这可能有助于对淋巴结进行更好的诊断评估。

目的

确定DECT中颈部、腋窝和腹股沟淋巴结IC的标准值。

材料与方法

从机构PACS中回顾性收集297例接受颈部、胸部、腹部-盆腔或这些部位联合的门静脉期DECT扫描患者的影像数据。检查区域目前无恶性肿瘤、炎症或创伤病史。对于每个检查区域,使用99例患者的数据。分别测量三个最大淋巴结、主要动脉、主要静脉和检查区域局部肌肉的IC。

结果

将淋巴结的IC与动脉、静脉、肌肉或它们的组合进行归一化处理,并未导致值范围减小。当使用每个区域IC的绝对值时,发现IC的范围和置信区间(CI)最小。由此得出淋巴结IC的平均值(95%CI):颈部为2.09mg/mL(2.00 - 2.18mg/mL),腋窝为1.24mg/mL(1.16 - 1.33mg/mL),腹股沟为1.11mg/mL(1.04 - 1.17mg/mL)。

结论

本研究表明,考虑到所使用的对比剂注射方案,双层CT中淋巴结IC的标准值可用于区分健康和病理性淋巴结。