Cornea, Cataract and External Diseases, Johns Hopkins Wilmer Eye Institute, Baltimore, Maryland, USA.
Ophthalmology Department, McGill University Health Centre, Montreal, Quebec, Canada.
Br J Ophthalmol. 2020 Nov;104(11):1596-1600. doi: 10.1136/bjophthalmol-2019-314548. Epub 2020 Feb 17.
BACKGROUND/AIM: To compare visual and refractive outcomes, changes in intraocular pressure (IOP), and complications of femtosecond laser-assisted cataract surgery (FLACS) to conventional phacoemulsification surgery (CPS) in paired eyes from the same patients.
This is a secondary analysis of an intraindividual, randomised, controlled clinical trial including 110 paired eyes from 55 patients that were randomised into either FLACS or CPS groups. Outcomes were recorded at baseline and postoperatively during a 3-month follow-up period.
Uncorrected distance visual acuity and corrected distance visual acuity were similar between FLACS and CPS over the follow-up period (p>0.05). The mean absolute refractive error was not significantly different between the two groups at postoperative month 1 (POM1) (0.3±0.2 D in FLACS vs 0.4±0.3 D in CPS, p=0.18) and month 3 (POM3) (0.3±0.3 D in FLACS vs 0.3±0.3 D in CPS, p=0.71). IOP was statistically higher in the FLACS group on postoperative day 1 (20.6±5.7 mm Hg for FLACS and 18.0±4.9 mm Hg for CPS, p=0.01). However, it was similar between the two groups subsequently (p>0.05). Intraoperatively, one case of posterior capsular block syndrome was observed in the FLACS group. Postoperatively, one case of newly developed glaucoma was observed in the FLACS group and one case of retinal tears in the CPS group.
The 3-month postoperative refractive and visual outcomes were comparable between FLACS and CPS in paired eyes from the same patients. Complication rate was low in the study population.
背景/目的:比较同一患者配对眼中飞秒激光辅助白内障手术(FLACS)与传统超声乳化白内障吸除术(CPS)的视力和屈光结果、眼内压(IOP)变化以及并发症。
这是一项个体内随机对照临床试验的二次分析,共纳入 55 例患者的 110 对眼,随机分为 FLACS 组或 CPS 组。在 3 个月的随访期间记录基线和术后的结果。
在随访期间,FLACS 组和 CPS 组的未矫正远视力和矫正远视力相似(p>0.05)。两组术后 1 个月(POM1)(FLACS 组为 0.3±0.2 D,CPS 组为 0.4±0.3 D,p=0.18)和术后 3 个月(POM3)(FLACS 组为 0.3±0.3 D,CPS 组为 0.3±0.3 D,p=0.71)的平均绝对屈光误差无显著差异。FLACS 组术后第 1 天的 IOP 显著高于 CPS 组(FLACS 组为 20.6±5.7 mm Hg,CPS 组为 18.0±4.9 mm Hg,p=0.01)。然而,随后两组间的 IOP 相似(p>0.05)。术中,FLACS 组观察到 1 例后囊膜下混浊。术后,FLACS 组发生 1 例新发青光眼,CPS 组发生 1 例视网膜裂孔。
同一患者配对眼中,FLACS 与 CPS 的术后 3 个月屈光和视力结果相当。研究人群的并发症发生率较低。