School of Occupational Therapy, College of Medicine, I-Shou University, Kaohsiung City, Taiwan, Republic of China.
School of Occupational Therapy, College of Medicine, I-Shou University, Kaohsiung City, Taiwan, Republic of China; Department of Physical Medicine and Rehabilitation E-Da Hospital, Kaohsiung City, Taiwan, Republic of China.
Arch Phys Med Rehabil. 2020 Aug;101(8):1332-1337. doi: 10.1016/j.apmr.2020.01.014. Epub 2020 Feb 25.
To investigate the psychometric properties and efficiency of the computerized adaptive testing system for measuring self-care performance (CAT-SC). The psychometric properties included intrarater and interrater reliabilities, concurrent validity, minimal detectable change, minimal important difference, and responsiveness.
Criterion standard study.
A teaching hospital.
A convenience sample of 60 caregivers of children with developmental disabilities was recruited at the initial assessment, and 95% of the children (N=57) were followed-up at 3 and 6 months.
Not applicable.
The CAT-SC and the Pediatric Evaluation of Disability Inventory Chinese version were used at the initial assessment. We assessed the CAT-SC and asked caregivers to rate children's changes in self-care performance with a separate question rated on a 15-point Likert-type scale at the 3- and 6-month follow-ups.
The CAT-SC had excellent intrarater and interrater reliabilities (intraclass coefficient=0.99 and 0.92, respectively), high concurrent validity with the Pediatric Evaluation of Disability Inventory (r=0.91-0.92), and trivial to small responsiveness at 3- and 6-month follow-ups (effect size=0.02 and 0.12, standardized response mean=0.08 and 0.33). The minimal detectable change of intrarater reliabilities and the minimal important difference at the first follow-up were 0.22 and 0.17 logits, respectively. The administration time of the CAT-SC was about 5 minutes.
The results of our study validated the sound psychometric properties and good efficiency of the CAT-SC. Moreover, the values of the minimal detectable change and minimal smallest change can be used as a reference for clinicians and caregivers to interpret children's progress.
研究测量自我护理能力的计算机自适应测试系统(CAT-SC)的心理计量学特性和效率。心理计量学特性包括内部信度、外部信度、同时效度、最小可检测变化、最小临床重要差异和反应度。
标准对照研究。
教学医院。
在初始评估时,通过便利抽样招募了 60 名发育障碍儿童的照顾者,其中 95%(N=57)的儿童在 3 个月和 6 个月时进行了随访。
无。
在初始评估时使用 CAT-SC 和儿童残疾评估量表中文版本。我们评估了 CAT-SC,并在 3 个月和 6 个月的随访中通过单独的问题,让照顾者使用 15 点 Likert 量表对儿童的自我护理能力变化进行评分。
CAT-SC 的内部信度和外部信度都非常高(组内相关系数分别为 0.99 和 0.92),与儿童残疾评估量表具有高度的同时效度(r 值为 0.91-0.92),在 3 个月和 6 个月的随访中具有微小到中等的反应度(效应量分别为 0.02 和 0.12,标准化反应均值分别为 0.08 和 0.33)。内部信度的最小可检测变化和首次随访的最小临床重要差异分别为 0.22 和 0.17 对数单位。CAT-SC 的管理时间约为 5 分钟。
本研究结果验证了 CAT-SC 的良好心理计量学特性和效率。此外,最小可检测变化和最小临床重要差异的数值可以作为临床医生和照顾者解释儿童进展的参考。