Chen Yujia, Zhou Weimin, Hagen Charlotte K, Olivo Alessandro, Anastasio Mark A
Opt Express. 2020 Jan 6;28(1):1-19. doi: 10.1364/OE.28.000001.
Edge-illumination X-ray phase-contrast tomography (EIXPCT) is an emerging technique that enables practical phase-contrast imaging with laboratory-based X-ray sources. A joint reconstruction method was proposed for reconstructing EIXPCT images, enabling novel flexible data-acquisition designs. However, only limited efforts have been devoted to optimizing data-acquisition designs for use with the joint reconstruction method. In this study, several promising designs are introduced, such as the constant aperture position (CAP) strategy and the alternating aperture position (AAP) strategy covering different angular ranges. In computer-simulation studies, these designs are analyzed and compared. Experimental data are employed to test the designs in real-world applications. All candidate designs are also compared for their implementation complexity. The tradeoff between data-acquisition time and image quality is discussed.
边缘照明X射线相衬断层扫描(EIXPCT)是一种新兴技术,它能够利用基于实验室的X射线源进行实际的相衬成像。提出了一种联合重建方法来重建EIXPCT图像,从而实现新颖灵活的数据采集设计。然而,在优化与联合重建方法配合使用的数据采集设计方面,所做的工作有限。在本研究中,介绍了几种有前景的设计,例如覆盖不同角度范围的恒定孔径位置(CAP)策略和交替孔径位置(AAP)策略。在计算机模拟研究中,对这些设计进行了分析和比较。采用实验数据在实际应用中测试这些设计。还比较了所有候选设计的实现复杂度。讨论了数据采集时间和图像质量之间的权衡。