To evaluate the reliability of different methods to normalize pelvic floor muscles (PFM) electromyography (EMG).
Thirty nulliparous women (23.9 ± 3.2 years), free from PFM dysfunction, completed two test sessions 7 days apart. For EMG normalization, signals were acquired during four different tasks using a vaginal probe in situ: PFM maximal voluntary contraction (MVC) and three daily activities with increased intra-abdominal pressure (coughing, Valsalva maneuver, and abdominal contraction). The intraclass correlation coefficients (ICC), standard error of measurement (SEM), relative standard error of measurement (%SEM), and minimal detectable change (MDC) were calculated for each variable.
ICC values for test-retest reliability of normalization methods ranged from 0.61 to 0.95. The highest values were obtained for mean root mean square (RMS) of the abdominal contraction and peak RMS of PFM-MVC. Normalization using RMS of PFM-MVC showed the lowest values of SEM and MDC.
The normalization of EMG data is considered a fundamental part of EMG investigations. These findings suggest that the normalization of PFM-EMG by either peak RMS of PFM-MVC or mean and peak RMS of abdominal contraction has excellent reliability and it can be applied in studies involving the evaluation of young women.
评估不同方法对盆底肌肌电图(PFM-EMG)进行归一化的可靠性。
30 名无生育史的女性(23.9±3.2 岁),无盆底肌功能障碍,在 7 天内完成了两次测试。对于 EMG 归一化,使用阴道探头原位采集了四种不同任务下的信号:PFM 最大自主收缩(MVC)和三种增加腹内压的日常活动(咳嗽、瓦尔萨尔手法和腹部收缩)。计算了每个变量的组内相关系数(ICC)、测量标准误差(SEM)、相对测量标准误差(%SEM)和最小可检测变化(MDC)。
归一化方法的测试-重测可靠性的 ICC 值范围为 0.61 至 0.95。腹收缩的 RMS 平均值和 PFM-MVC 的 RMS 峰值的归一化值最高。使用 PFM-MVC 的 RMS 进行归一化显示出最小的 SEM 和 MDC 值。
EMG 数据的归一化被认为是 EMG 研究的基本部分。这些发现表明,通过 PFM-MVC 的 RMS 峰值或腹部收缩的 RMS 平均值和峰值对 PFM-EMG 进行归一化具有极好的可靠性,可应用于评估年轻女性的研究。