Suppr超能文献

[床旁实时超声测量动脉峰值速度变化对液体反应性预测的诊断准确性:一项Meta分析]

[Diagnostic accuracy of artery peak velocity variation measured by bedside real-time ultrasound for prediction of fluid responsiveness: a Meta-analysis].

作者信息

Pei Yinghao, Yang Yang, Feng Ying, He Shuyin, Zhou Jiang, Jiang Hua, Wang Xing

机构信息

Department of Intensive Care Unit, Affiliated Hospital of Nanjing University of Chinese Medicine, Jiangsu Provincial Hospital of Chinese Medicine, Nanjing 210029, Jiangsu, China.

Department of General Medicine, Fengxian People's Hospital, Xuzhou 221700, Jiangsu, China.

出版信息

Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2020 Jan;32(1):99-105. doi: 10.3760/cma.j.cn121430-20191226-00018.

Abstract

OBJECTIVE

To evaluate the diagnostic value of ultrasonic measurement of artery peak velocity variation (ΔVpeak) on predicting fluid responsiveness in critically ill patients.

METHODS

Databases of PubMed, Embase, Cochrane Library, SinoMed, Wanfang, CNKI and VIP were retrieved from the establishment of the database to November 2019. The retrieval literatures were about the research of ΔVpeak used to judge fluid responsiveness. According to the inclusion and exclusion criteria, the relevant literatures were screened by two researchers, and the data of the included literatures were extracted. The quality of literatures was evaluated by quality assessment of diagnostic accuracy studies (QUADAS). Meta Dics 1.4 software was used to analyze the literatures that met the quality standard by Meta-analysis. The pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR) and diagnostic odds ratio (DOR) were calculated. The summary receiver operating characteristic (SROC) curve was drawn and the area under SROC curve (AUC) was calculated. The χ test and Spearman correlation coefficient were used to analyze heterogeneity, and Deek test was used to analyze publication bias.

RESULTS

A total of 1 854 patients were enrolled in 31 studies, including 11 domestic studies and 20 foreign studies. Using 14 items of QUADAS to evaluate the quality of literatures, it was found that the enrolled literatures were all in Grade A, indicating that the overall quality of literatures was high. The scattered distribution of SROC curve was not "shoulder arm shape", and Spearman correlation coefficient was 0.062 (P = 0.710), so there was no threshold effect. The heterogeneity test showed that I = 57.2% (P = 0.001), indicating that there was a certain degree of heterogeneity among the studies, and the source of heterogeneity was non threshold effect. Meta regression analysis showed that the reason for heterogeneity was the method of volume load test [DOR = 3.87, 95% confidence interval (95%CI) was 1.56-9.57, P = 0.004 8]. According to the results of heterogeneity analysis, there was no significant heterogeneity (I = 10.6, P = 0.288 5) among the studies after removing the samples of the passive leg raising (PLR) instead of the volume expansion. A meta-analysis was done with random effects model. The results showed that the pooled DOR was 23.85 (95%CI was 17.57 to 32.37), pooled sensitivity was 0.82 (95%CI was 0.80 to 0.85), pooled specificity was 0.83 (95%CI was 0.80 to 0.85), pooled PLR was 4.17 (95%CI was 3.58 to 4.86), and pooled NLR was 0.22 (95%CI was 0.18 to 0.28). The AUC was 0.901 2 (95%CI was 0.88 to 0.93), and Q index was 0.832 5. The results of Deek funnel plot showed that there was no published bias in all the studies (P = 0.19).

CONCLUSIONS

Ultrasonic measurement of ΔVpeak has a high value in predicting fluid responsiveness. It is a reliable parameter for the evaluation of shock, critical illness and surgical operation population who need to monitor the fluid responsiveness.

摘要

目的

评估超声测量动脉峰值流速变化(ΔVpeak)对预测危重症患者液体反应性的诊断价值。

方法

检索PubMed、Embase、Cochrane图书馆、中国生物医学文献数据库、万方数据库、中国知网和维普数据库,检索时间从各数据库建库至2019年11月。检索关于ΔVpeak用于判断液体反应性的研究文献。根据纳入和排除标准,由两名研究人员筛选相关文献,并提取纳入文献的数据。采用诊断准确性研究的质量评估(QUADAS)对文献质量进行评价。使用Meta Dics 1.4软件对符合质量标准的文献进行Meta分析。计算合并敏感度、特异度、阳性似然比(PLR)、阴性似然比(NLR)和诊断比值比(DOR)。绘制汇总受试者工作特征(SROC)曲线并计算SROC曲线下面积(AUC)。采用χ检验和Spearman相关系数分析异质性,采用Deek检验分析发表偏倚。

结果

31项研究共纳入1854例患者,其中国内研究11项,国外研究20项。采用QUADAS的14项指标评价文献质量,发现纳入文献均为A级,表明文献总体质量较高。SROC曲线呈散点分布,无“肩臂形”,Spearman相关系数为0.062(P = 0.710),因此不存在阈值效应。异质性检验显示I² = 57.2%(P = 0.001),表明各研究间存在一定程度的异质性,异质性来源为非阈值效应。Meta回归分析显示异质性的原因是容量负荷试验方法[DOR = 3.87,95%置信区间(95%CI)为1.56 - 9.57,P = 0.0048]。根据异质性分析结果,剔除被动抬腿(PLR)而非容量扩充样本后的研究间无显著异质性(I² = 10.6,P = 0.2885)。采用随机效应模型进行Meta分析。结果显示,合并DOR为23.85(95%CI为17.57至32.37),合并敏感度为0.82(95%CI为0.80至0.85),合并特异度为0.83(95%CI为0.80至0.85),合并PLR为4.17(95%CI为3.58至4.86),合并NLR为0.22(95%CI为0.18至0.28)。AUC为0.9012(95%CI为0.88至0.93),Q指数为0.8325。Deek漏斗图结果显示所有研究均无发表偏倚(P = 0.19)。

结论

超声测量ΔVpeak对预测液体反应性具有较高价值。它是评估休克、危重症及需要监测液体反应性的手术人群的可靠参数。