Suppr超能文献

7年不良输血反应的发生率及分析:一项回顾性分析

Incidence and Analysis of 7 Years Adverse Transfusion Reaction: A Retrospective Analysis.

作者信息

Saha Suryatapa, Krishna Deepthi, Prasath Raghuram, Sachan Deepti

机构信息

1Present Address: Department of Transfusion Medicine, Apollo Gleneagles Hospital, Calcutta, India.

2Department of Transfusion Medicine, Gleneagles Global Health City, Chennai, 600100 India.

出版信息

Indian J Hematol Blood Transfus. 2020 Jan;36(1):149-155. doi: 10.1007/s12288-019-01174-x. Epub 2019 Aug 30.

Abstract

Safe blood transfusion is the primary need of all the health care delivery system. Though with the advances of transfusion medicine, the incidences of transfusion risk is gradually reduced, but the adverse transfusion reaction (ATR) of non hemolytic type still prevails. The purpose of this study was to estimate the incidence and pattern of transfusion-related adverse events at our centre. The present retrospective observational study was conducted in the Department of Transfusion Medicine from April 2011 to April 2018, at a multi-organ transplant centre in South India. All the Adverse transfusion reactions were investigated in detail in the blood bank for the clerical errors, immunohematology workup and classified according to their nature with imputability assessment. A total of 140 ATR were reported out of 100,569 blood components distributed during the study period. After the analysis and workup of the reported reactions, majority of the reactions were observed in males (71%, n = 99). Most common symptom presented was Itching/Rashes in 43.6% (n = 61) ATR. Allergic reactions (51.4%, n = 72), were the most commonly encountered ATR followed by FNHTR (25.7%, n = 36). FFP transfusions (0.2%) contributed to the majority of the reactions followed by Red cell transfusion (0.15%). ATR were observed maximum in Hepato-biliary disease and liver transplantation patients (62%) followed by oncology patients (15%). The overall incidence of ATR in our study is 0.14% which is comparatively low compared to other studies due to well established hemovigilance systems. Adoption of more equipped methods & sensitive technology in various areas of blood banking will help to bring down the unwanted adverse transfusion reactions.

摘要

安全输血是所有医疗保健系统的首要需求。尽管随着输血医学的进步,输血风险的发生率逐渐降低,但非溶血型的不良输血反应(ATR)仍然普遍存在。本研究的目的是评估我们中心输血相关不良事件的发生率和模式。本回顾性观察研究于2011年4月至2018年4月在印度南部的一个多器官移植中心的输血医学科进行。在血库中对所有不良输血反应进行了详细调查,以查找文书错误、免疫血液学检查,并根据其性质进行分类并进行责任评估。在研究期间分发的100,569个血液成分中,共报告了140例ATR。在对报告的反应进行分析和检查后,大多数反应发生在男性(71%,n = 99)。最常见的症状是瘙痒/皮疹,占43.6%(n = 61)的ATR。过敏反应(51.4%,n = 72)是最常遇到的ATR,其次是发热性非溶血性输血反应(FNHTR,25.7%,n = 36)。新鲜冰冻血浆输血(0.2%)导致的反应最多,其次是红细胞输血(0.15%)。在肝胆疾病和肝移植患者中观察到的ATR最多(62%),其次是肿瘤患者(15%)。我们研究中ATR的总体发生率为0.14%,由于建立了完善的血液警戒系统,与其他研究相比相对较低。在血库的各个领域采用更先进的方法和敏感技术将有助于减少不必要的不良输血反应。

相似文献

1
Incidence and Analysis of 7 Years Adverse Transfusion Reaction: A Retrospective Analysis.7年不良输血反应的发生率及分析:一项回顾性分析
Indian J Hematol Blood Transfus. 2020 Jan;36(1):149-155. doi: 10.1007/s12288-019-01174-x. Epub 2019 Aug 30.

引用本文的文献

4
Tachycardia and fever after packed red cell (PRC) infusion: A case report.输注浓缩红细胞后出现心动过速和发热:一例报告。
J Family Med Prim Care. 2023 Jul;12(7):1457-1459. doi: 10.4103/jfmpc.jfmpc_647_22. Epub 2023 Jul 14.

本文引用的文献

10
Anaphylactic transfusion reactions.
Transfusion. 2011 Nov;51(11):2265-6. doi: 10.1111/j.1537-2995.2011.03404.x.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验