Kohta Masaaki, Fujita Atsushi, Matsuo Kazuya, Yamashita Shunsuke, Kohmura Eiji
Department of Neurosurgery, Kobe University Graduate School of Medicine, 7-5-1, Kusunoki-cho, Chuo-ku, Kobe 650-0017, Japan.
Radiol Case Rep. 2020 Mar 6;15(5):542-544. doi: 10.1016/j.radcr.2020.02.003. eCollection 2020 May.
We describe a unique technique to reduce the amount of contrast medium by injecting diluted contrast medium from the microcatheter during neurointervention. A patient with severe renal impairment due to polycystic kidney was referred for endovascular surgery for wide-neck middle cerebral artery aneurysm. In order to reduce the amount of contrast medium, contrast medium was injected from the microcatheter placed in the middle cerebral artery during coil embolization; renal function decline was not observed after the procedure. This technique, therefore, reduces the amount of contrast medium and enables one to perform coil embolization safely.
我们描述了一种独特的技术,即在神经介入过程中通过微导管注入稀释的造影剂来减少造影剂的用量。一名因多囊肾导致严重肾功能损害的患者被转诊进行宽颈大脑中动脉瘤的血管内手术。为了减少造影剂的用量,在弹簧圈栓塞过程中从置于大脑中动脉的微导管注入造影剂;术后未观察到肾功能下降。因此,该技术减少了造影剂的用量,并使弹簧圈栓塞能够安全进行。