Abstract

Building renovations can adversely affect building occupants through the release of biological contaminants, gases and particulates. In this study, the research aim was to monitor the air quality of a renovated building and assess the impact of sick building syndrome (SBS) on the occupants. Post occupancy monitoring of the building was carried out after two months occupancy for the following environmental parameters: airborne microflora using an air sampler (SAS super 180) and a hand-held monitoring device (Graywolf advance sense IQ-610) to measure total volatile organic compounds (TVOC), CO, CO and temperature and relative humidity in each office environment. In addition, an online (Qualtrics) structured questionnaire was used to assess occupants' perceptions of the indoor environment. Results of the airborne flora showed 833 cfu/m recovered on a Malt Extract Agar (MEA) plate in the morning and 1213 cfu/m in the afternoon. A similar result was noticed on a Plate Count Agar (PCA) plate during the morning period (731 cfu/m) and afternoon (1358 cfu/m). Results of TVOC monitored over one week showed that the first two days of monitoring had a high reading that peaked at 10,837 ppb and that the CO concentration during that period was 1163 ppm. Online questionnaire analysis indicates that a majority of the staff who took part in the survey experienced some form of health abnormality, including headache, shortness of breath, itchy eyes/ears, loss of concentration and so on, especially in the first few weeks of returning to the office. The results from the study indicate that a large proportion (41%) of the respondents experienced thermal discomfort as a result of varying room temperature during their working hours. A high number of female participants experienced some form of SBS as compared to their male counterparts. The study findings show a direct relationship between high airborne mold counts, TVOC and adverse staff health perception of the building. The study raised a number of opportunities for estate managers to improve building performance based on occupants' preferences.

摘要

建筑物翻新可能会通过释放生物污染物、气体和颗粒物对建筑物居住者产生不利影响。在这项研究中,研究目的是监测翻新建筑物的空气质量,并评估病态建筑综合征 (SBS) 对居住者的影响。在入住两个月后对建筑物进行了入住后监测,以监测以下环境参数:使用空气采样器(SAS super 180)和手持式监测设备(Graywolf advance sense IQ-610)测量总挥发性有机化合物 (TVOC)、CO、CO 和温度和相对湿度在每个办公环境中。此外,还使用在线(Qualtrics)结构化问卷评估了居住者对室内环境的看法。空气中微生物群的结果显示,早上在麦芽提取物琼脂 (MEA) 平板上回收了 833 cfu/m,下午回收了 1213 cfu/m。在早上(731 cfu/m)和下午(1358 cfu/m)期间,在平板计数琼脂 (PCA) 平板上也注意到了类似的结果。一周内监测到的 TVOC 结果显示,监测的前两天读数较高,峰值为 10,837 ppb,在此期间 CO 浓度为 1163 ppm。在线问卷分析表明,大多数参与调查的员工都经历过某种形式的健康异常,包括头痛、呼吸急促、眼睛/耳朵发痒、注意力不集中等,尤其是在返回办公室的头几周。研究结果表明,由于工作时间内房间温度的变化,相当大比例(41%)的受访者感到不适。与男性相比,女性参与者中出现某种形式 SBS 的人数较多。研究结果表明,空气中霉菌计数高、TVOC 高与员工对建筑物健康感知不良之间存在直接关系。该研究为房地产经理提供了一些机会,根据居住者的偏好来提高建筑物的性能。

相似文献

7
Summary of human responses to ventilation.人体对通气的反应总结。
Indoor Air. 2004;14 Suppl 7:102-18. doi: 10.1111/j.1600-0668.2004.00279.x.

引用本文的文献

本文引用的文献

4
Indoor air quality in public utility environments-a review.公共事业环境中的室内空气质量——综述
Environ Sci Pollut Res Int. 2017 Apr;24(12):11166-11176. doi: 10.1007/s11356-017-8567-7. Epub 2017 Feb 24.
7
Thermal comfort and gender: a literature review.热舒适与性别:文献综述。
Indoor Air. 2012 Apr;22(2):96-109. doi: 10.1111/j.1600-0668.2011.00747.x. Epub 2011 Nov 1.
8
The medical effects of mold exposure.接触霉菌的医学影响。
J Allergy Clin Immunol. 2006 Feb;117(2):326-33. doi: 10.1016/j.jaci.2005.12.001.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验