在至少 5 年的随访中测量反式肩关节置换术的体内体积和线性磨损。

In vivo volumetric and linear wear measurement of reverse shoulder arthroplasty at minimum 5-year follow-up.

机构信息

Imaging Research Laboratories, Robarts Research Institute, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada; School of Biomedical Engineering, Western University, London, ON, Canada; Lawson Health Research Institute, London, ON, Canada.

Lawson Health Research Institute, London, ON, Canada; Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada.

出版信息

J Shoulder Elbow Surg. 2020 Aug;29(8):1695-1702. doi: 10.1016/j.jse.2019.11.031. Epub 2020 Mar 16.

Abstract

BACKGROUND

Reverse shoulder arthroplasty is quickly becoming the most frequently performed glenohumeral joint replacement. The purpose of this study was to evaluate the volumetric and linear wear rates of ultrahigh-molecular-weight polyethylene humeral liners in vivo at a minimum 5-year follow-up.

METHODS

Radiostereometric analysis was used to image 15 patients at terminal range of motion in forward flexion, abduction, external rotation, and internal rotation and with the arm at the side. The relative position and orientation of the glenosphere and polyethylene were identified for each arm position. The apparent intersection of the glenosphere into the polyethylene was recorded as wear. Mean volumetric and linear wear rates were recorded, and Pearson correlation coefficients were applied to the 36-mm liners to assess the relationship between the wear rate and term of service.

RESULTS

The mean reverse shoulder arthroplasty term of service at the time of imaging was 8 ± 1 years (range, 6-11 years). The mean volumetric and linear wear rates for the 36-mm liners (n = 13) were 42 ± 22 mm/yr (r = 0.688, P = .009) and 0.11 ± 0.03 mm/yr (r = 0.767, P = .002), respectively. The mean volumetric and linear wear rates for the 42-mm liners (n = 2) were 114 ± 44 mm/yr and 0.17 ± 0.01 mm/yr, respectively. No single arm position was able to capture all recorded wear individually.

CONCLUSION

This study showed volumetric and linear wear rates of approximately 40 mm/yr and 0.1 mm/yr, respectively, for the 36-mm polyethylene liners. The 42-mm liners showed higher wear rates, although a greater number of subjects is required for conclusive results. In vivo wear of reverse total shoulder arthroplasty is multidirectional and perceptible.

摘要

背景

反式肩关节置换术正迅速成为最常施行的盂肱关节置换术。本研究的目的是评估在至少 5 年的随访中,体内超高分子量聚乙烯肱骨衬垫的体积和线性磨损率。

方法

采用放射立体测量分析法对 15 例患者在肩关节前屈、外展、外旋和内旋的终末活动范围内进行成像,并使手臂处于体侧。对每个臂位的肱骨头和聚乙烯的相对位置和方向进行识别。记录肱骨头切入聚乙烯的明显交点作为磨损。记录平均体积和线性磨损率,并对 36mm 衬垫应用 Pearson 相关系数,以评估磨损率与使用期限之间的关系。

结果

在进行成像时,反式肩关节置换术的平均使用期限为 8 ± 1 年(范围为 6-11 年)。13 个 36mm 衬垫的平均体积和线性磨损率分别为 42 ± 22mm/yr(r = 0.688,P =.009)和 0.11 ± 0.03mm/yr(r = 0.767,P =.002)。2 个 42mm 衬垫的平均体积和线性磨损率分别为 114 ± 44mm/yr 和 0.17 ± 0.01mm/yr。没有任何一个手臂位置能够单独捕捉到所有记录的磨损。

结论

本研究显示 36mm 聚乙烯衬垫的体积和线性磨损率分别约为 40mm/yr 和 0.1mm/yr。42mm 衬垫的磨损率较高,但需要更多的受试者才能得出结论。体内反式全肩关节置换术的磨损是多方向的,可感知的。