Comparison of visual analog shade matching, a digital visual method with a cross-polarized light filter, and a spectrophotometer for dental color matching.

机构信息

Assistant Professor, Department of Prosthodontics, Faculty of Dentistry, Universidad de Los Andes, Santiago, Chile.

Research Assistant, Department of Prosthodontics, Faculty of Dentistry, Universidad de Los Andes, Santiago, Chile.

出版信息

J Prosthet Dent. 2021 Mar;125(3):511-516. doi: 10.1016/j.prosdent.2020.02.002. Epub 2020 Mar 17.

Abstract

STATEMENT OF PROBLEM

During the selection of tooth color, subjective communication with the laboratory and an incorrect color registration technique can lead to a poor color match of a restoration to adjacent teeth and oral structures.

PURPOSE

The purpose of this cross-sectional study was to compare color registration and color matching in a young Chilean population with 3 different methods: visual with a shade guide, digital visual with a cross-polarized filter, and instrumental with a spectrophotometer.

MATERIAL AND METHODS

A total of 60 young volunteers were selected for tooth color registration of the maxillary right central incisor by using 3 different methods. Tooth color registration was performed using the CIELab and ΔE coordinate system.

RESULTS

Significant differences were detected between the coordinates recorded by the visual analog method in comparison with the other 2 methods. In contrast, no significant differences were found between the L∗ and b∗ coordinates of the spectrophotometer and the digital visual method with use of a cross-polarization filter. The ΔE obtained between the visual shade and spectrophotometer was 7.35, and the ΔE between the digital visual method with the use of a cross-polarization filter and the spectrophotometer was 6.12.

CONCLUSIONS

No statistically significant differences were observed in the digital image with the cross-polarization filter and the spectrophotometer in the L∗ and b∗ coordinate of the CIELab system. In contrast, the visual analog method led to large differences with the other methods under study. The ΔE of the digital visual method with the use of cross-polarization filters and the spectrophotometer was 6.2, considered as an acceptable color mismatch (<ΔE 6.8).

摘要

问题陈述

在选择牙齿颜色时,与实验室的主观沟通以及不正确的颜色登记技术可能导致修复体与邻牙和口腔结构的颜色匹配不佳。

目的

本横断面研究的目的是比较 3 种不同方法(比色板目视比色、交叉偏振滤光片数字视觉比色和分光光度计比色)在年轻智利人群中的颜色登记和颜色匹配。

材料和方法

选择 60 名年轻志愿者,使用 3 种不同方法对右上中切牙进行牙齿颜色登记。采用 CIELab 和 ΔE 坐标系统进行牙齿颜色登记。

结果

与其他 2 种方法相比,视觉模拟法记录的坐标存在显著差异。相比之下,分光光度计和带有交叉偏振滤光片的数字视觉法的 L和 b坐标之间未发现显著差异。视觉比色法与分光光度计之间的 ΔE 为 7.35,带有交叉偏振滤光片的数字视觉法与分光光度计之间的 ΔE 为 6.12。

结论

在 CIELab 系统的 L和 b坐标中,带有交叉偏振滤光片的数字图像与分光光度计之间未观察到统计学上的显著差异。相比之下,视觉模拟法与其他研究方法之间存在较大差异。带有交叉偏振滤光片的数字视觉法与分光光度计的 ΔE 为 6.2,被认为是可接受的颜色匹配(<ΔE 6.8)。