Suppr超能文献

使用微传感器和眼罩助手改善对遮盖治疗依从性的监测。

Improved monitoring of adherence with patching treatment using a microsensor and Eye Patch Assistant.

机构信息

Salus University Pennsylvania College of Optometry, Elkins Park, Pennsylvania.

Panorama Windows Ltd. New York, New York.

出版信息

J AAPOS. 2020 Apr;24(2):96.e1-96.e7. doi: 10.1016/j.jaapos.2020.01.006. Epub 2020 Mar 18.

Abstract

BACKGROUND

Use of a microsensor has been suggested to monitor patching adherence. Application has been limited because the microsensor's small size makes it easy to lose and a swallowing risk. We designed the Eye Patch Assistant (EPA) to hold the small microsensor in place and reduce the risk of loss or swallowing. This study reports the accuracy, precision, ease of use, and comfort for patching with EPA (patch+EPA) to monitor adherence.

METHODS

Adults (N = 13) wore an adhesive patch alone or a patch+EPA for 2 hours each, recorded wear time, and completed an ease of use/comfort questionnaire; 30 children wore a patch or patch+EPA and completed the questionnaire. Sensor sampling interval was every 5 minutes or every 1 minute. Sensor accuracy and precision were evaluated by Bland-Altman analysis and 95% limits of agreement, and questionnaire scores compared by Wilcoxon tests.

RESULTS

With 5-minute sampling, we found excellent accuracy for adults (mean actual vs recorded time difference, 1.4 minutes) and children (mean difference, -0.9 min). We found high precision for both adults and children (95% limits of agreement half widths of 6.4 minutes and 1.9 minutes, respectively). In adults, the ease of use score for the patch+EPA was lower than the patch (P < 0.01), but the comfort score for the patch+EPA was higher (P < 0.01). For children, scores did not differ significantly. The patch+EPA functioned well between 45° and 82°F.

CONCLUSIONS

The patch+EPA was well accepted and monitored adherence accurately and precisely.

摘要

背景

使用微传感器已被建议用于监测贴片的贴合度。但由于微传感器体积小,容易丢失且存在吞咽风险,其应用受到限制。我们设计了眼部贴片辅助器(EPA)来固定小的微传感器,以降低丢失或吞咽的风险。本研究报告了使用 EPA(贴片+EPA)监测贴合度的准确性、精密度、易用性和舒适性。

方法

成人(N=13)分别单独佩戴粘性贴片或贴片+EPA 各 2 小时,记录佩戴时间,并完成易用性/舒适性问卷;30 名儿童佩戴贴片或贴片+EPA 并完成问卷。传感器采样间隔为每 5 分钟或每 1 分钟。通过 Bland-Altman 分析和 95%一致性界限评估传感器的准确性和精密度,并通过 Wilcoxon 检验比较问卷评分。

结果

采用 5 分钟的采样间隔,我们发现成人(实际时间与记录时间的平均差值为 1.4 分钟)和儿童(平均差值为-0.9 分钟)的准确性非常好。我们发现成人和儿童的精密度都很高(95%一致性界限的半宽分别为 6.4 分钟和 1.9 分钟)。在成人中,贴片+EPA 的易用性评分低于贴片(P<0.01),但贴片+EPA 的舒适性评分更高(P<0.01)。对于儿童,评分没有显著差异。贴片+EPA 在 45°F 至 82°F 之间功能良好。

结论

贴片+EPA 得到了很好的接受,能够准确、精确地监测贴合度。

相似文献

引用本文的文献

1
Interventions for improving adherence to amblyopia treatments in children.改善儿童弱视治疗依从性的干预措施。
Cochrane Database Syst Rev. 2025 Jul 2;7(7):CD015820. doi: 10.1002/14651858.CD015820.pub2.
4
Leveraging neural plasticity for the treatment of amblyopia.利用神经可塑性治疗弱视。
Surv Ophthalmol. 2024 Sep-Oct;69(5):818-832. doi: 10.1016/j.survophthal.2024.04.006. Epub 2024 May 18.
7
Recent Advances in Screening and Treatment for Amblyopia.弱视筛查与治疗的最新进展
Ophthalmol Ther. 2021 Dec;10(4):815-830. doi: 10.1007/s40123-021-00394-7. Epub 2021 Sep 9.

本文引用的文献

2
Assessing Agreement between Methods of Measurement.评估测量方法之间的一致性。
Clin Chem. 2017 Oct;63(10):1653-1654. doi: 10.1373/clinchem.2016.268870. Epub 2017 Jun 6.
7
Compliance with occlusion therapy for childhood amblyopia.儿童弱视的遮盖疗法依从性。
Invest Ophthalmol Vis Sci. 2013 Sep 17;54(9):6158-66. doi: 10.1167/iovs.13-11861.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验