The analytic and functional accuracy of a video densitometry system.

作者信息

McEachron D L, Gallistel C R, Eilbert J L, Tretiak O J

机构信息

Department of Bioscience, Drexel University, Philadelphia, PA 19104.

出版信息

J Neurosci Methods. 1988 Aug;25(1):63-74. doi: 10.1016/0165-0270(88)90121-5.

DOI:10.1016/0165-0270(88)90121-5
PMID:3221688
Abstract

Applications using radiotracers and quantitative film autoradiography are increasing dramatically in the neurosciences. Microcomputer-based image analyzing systems with video input have been developed to provide rapid quantification of autoradiographic images on relatively inexpensive systems. However, there has been some question as to whether such systems can reliably produce high levels of densitometric accuracy, especially when compared to mechanical scanners which are standard in research requiring extreme fidelity of measurement. We report methods and results from tests done to determine the analytical and functional accuracy of the Drexel Unix-based Microcomputer image Analysis System (DUMAS), which is a video densitometric system designed to provide quantitative data from autoradiograms. Analytical accuracy was determined by measuring photometric uniformity, the optical density transfer function, temporal stability, geometric uniformity, and flare. In addition, data are provided on the resolution of the system at several magnifications. Functional accuracy, the accuracy of the estimates of mean isotope concentrations in diverse neural structures, was determined by comparing the results obtained on the DUMAS system with the results from analyzing the same [14C]2-deoxyglucose images with two different Optronics P1000 systems. Our results show that, provided care is taken in the choice of a camera and a light source, the analytic accuracy of videodensitometry is high. Its functional accuracy is also high in that measurements of radioisotope concentrations in diverse neural structures made on the DUMAS system agree closely with the measurements from a properly adjusted Optronics P1000 system. The rapidity and economy of videodensitometry is not, therefore, obtained at the sacrifice of densitometric accuracy. Given adequately tested hardware and provided that suitable checks on instrument calibration and adjustment are made, the errors in autoradiographic quantification due to the image analyzing system itself are minor in comparison to other sources of error, including, as we show, variations in the user's delineation of the boundaries of neural structures.

摘要

相似文献

1
The analytic and functional accuracy of a video densitometry system.
J Neurosci Methods. 1988 Aug;25(1):63-74. doi: 10.1016/0165-0270(88)90121-5.
2
Electronic imaging in neuroscience.神经科学中的电子成像
Curr Protoc Neurosci. 2002 May;Chapter 2:Unit 2.4. doi: 10.1002/0471142301.ns0204s18.
3
Video and scanning microdensitometer-based imaging systems in autoradiographic densitometry.
J Neurosci Methods. 1984 Jun;11(2):89-100. doi: 10.1016/0165-0270(84)90028-1.
4
A microcomputer system for video image analysis and diagnostic microdensitometry.
Anal Quant Cytol Histol. 1986 Sep;8(3):201-9.
5
Computer-assisted quantification and image processing of whole-body autoradiograms.
J Pharmacol Methods. 1990 Nov;24(3):165-81. doi: 10.1016/0160-5402(90)90027-i.
6
Automatic quantitative evaluation of autoradiographic band films by computerized image analysis.通过计算机图像分析对放射自显影片条带进行自动定量评估。
Life Sci. 1993;53(20):PL331-6. doi: 10.1016/0024-3205(93)90566-l.
7
An inexpensive microcomputer-based image-analysis system: novel applications to quantitative autoradiography.一种基于微型计算机的低成本图像分析系统:在定量放射自显影中的新应用。
J Neurosci Methods. 1985 Feb;12(4):265-75. doi: 10.1016/0165-0270(85)90011-1.
8
Bone mass determination from microradiographs by computer-assisted videodensitometry. I. Methodology.通过计算机辅助视频密度测定法从显微放射照片测定骨量。I. 方法学。
Acta Radiol. 1988 Jul-Aug;29(4):465-72.
9
The evaluation of quantitative autoradiogram processing systems for cerebrovascular research.
J Neurosci Methods. 1988 May;24(1):11-25. doi: 10.1016/0165-0270(88)90029-5.
10
Fundamentals of quantitative autoradiography by computer densitometry for in situ hybridization, with emphasis on 33P.通过计算机密度测定法进行原位杂交的定量放射自显影基础,重点是33P。
J Histochem Cytochem. 1993 Dec;41(12):1767-76. doi: 10.1177/41.12.8245425.