Abstract

BACKGROUND

The progress of 3D imaging and manufacturing of implants has made it possible to achieve a custom-made concept in THA. The custom-made cementless femoral stem provides optimal implant stability combined with restoration of the native hip mechanics.

OBJECTIVE

The purpose of this study was to evaluate the long-term survivorship of custom-made hip femoral stems in two populations of patients undergoing THA: patients under 50 years old (young patients group) and patients with high-grade developmental dysplasia of the hip (DDH group).

METHODS

A series of 232 primary custom-made cementless THA stems were retrospectively evaluated in patients less than 50 years old at the time of surgery and at follow-up after an average of 20 years. A second series of 26 custom-made cementless stem THAs for late DDH (21 patients) including only Crowe grade III and grade IV were also retrospectively evaluated with an average follow-up of 16 years. The clinical and radiological evaluations were performed preoperatively and at yearly intervals.

RESULTS

For the young patient group, the follow-up ranged from 14 to 27 years. The HHS and the Merle D'Aubigne-Postel score significantly improved from preoperatively to a mean of 94.1 (range 48-100) and 15.9 (range 9-18), respectively. Taking stem revision for aseptic loosening as an endpoint, survivorship was 96.8% at 20 years (95% confidence interval, CI 95.1-98.5). For the DDH group, the follow-up ranged from 10 to 22 years. The mean HHS increased significantly from preoperative 49 ± 22 points to the most recent follow-up examination with 86 13 points and survivorship was 96.1% (95% CI, 92.7-99.9).

CONCLUSION

Custom-made femoral stems provide good functional outcome and long-term survivorship in two specific populations of patients undergoing THAs: patients under 50 years old with high expectations and patients with high-grade DDH.

摘要

背景

植入物的三维成像和制造技术的进步使得在全髋关节置换术(THA)中实现定制理念成为可能。定制的非骨水泥型股骨柄可提供最佳的植入稳定性,并恢复髋关节的自然力学。

目的

本研究的目的是评估定制髋关节股骨柄在两组接受THA的患者中的长期生存率:50岁以下患者(年轻患者组)和重度发育性髋关节发育不良患者(DDH组)。

方法

回顾性评估了一系列232例初次定制的非骨水泥型THA股骨柄,这些患者手术时年龄小于50岁,平均随访20年。还回顾性评估了第二组26例晚期DDH患者(21例)的定制非骨水泥型股骨柄THA,仅包括Crowe III级和IV级,平均随访16年。术前和每年进行临床和影像学评估。

结果

年轻患者组的随访时间为14至27年。髋关节Harris评分(HHS)和Merle D'Aubigne-Postel评分从术前到术后均显著改善,平均分别为94.1(范围48-100)和15.9(范围9-18)。以无菌性松动进行股骨柄翻修为终点,20年生存率为96.8%(95%置信区间,CI 95.1-98.5)。DDH组的随访时间为10至22年。平均HHS从术前的49±22分显著提高到最近一次随访时的86±13分,生存率为96.1%(95%CI,92.7-99.9)。

结论

定制股骨柄在两组接受THA的特定患者群体中提供了良好的功能结果和长期生存率:期望较高的50岁以下患者和重度DDH患者。