Suppr超能文献

全景高风险标志物与锥形束CT在下颌第三磨牙术前评估中的结果相关性

Correlation of panoramic high-risk markers with the cone beam CT findings in the preoperative assessment of the mandibular third molars.

作者信息

Al Ali Shaima, Jaber Mohamed

机构信息

Department of Oral Surgery, Hamdan Bin Mohamed College of Dental Medicine, United Arab Emirates.

College of Dentistry, Ajman University, United Arab Emirates.

出版信息

J Dent Sci. 2020 Mar;15(1):75-83. doi: 10.1016/j.jds.2019.08.006. Epub 2019 Oct 19.

Abstract

BACKGROUND/PURPOSE: Preoperative radiographic examination of mandibular third molars (MTM) is essential to prevent inferior alveolar nerve (IAN) injury. The aim of this study was to assess the panoramic radiography (PAN) signs considered as indicators of increased risk of IAN injury and to correlate them with the cone beam CT (CBCT) findings.

MATERIALS AND METHODS

58 patients who had MTMs extraction between January 2012 and January 2018. OPG were evaluated for the following signs: interruption of the roof of the canal, root darkening, roots deflection and narrowing, canal deviation, superimposition between the MTM roots and mandibular canal. Loss of canal cortication, root grooving, thinning and perforation of lingual cortex were assessed in CBCT images. Chi-square test and multivariate logistic regression tests were used to test the relationship between PAN signs and CBCT findings.

RESULTS

A total of 79 MTMs were examined. Loss of canal cortication in CBCT was seen in 22 (27.8%) of the cases. Root darkening in PAN images was the most frequent radiographic sign. Canal deviation and interruption of white line in PAN demonstrated a statistically significant correlation with the loss of canal cortication between the MTM and the mandibular canal on CBCT images (p = 0.004 and p = 0.012, respectively). No statistically significant association was observed for the other PAN signs and CBCT findings.

CONCLUSION

Canal deviation and interruption of white lines were associated with loss of canal cortication on CBCT, indicating a direct contact between the roots and the mandibular canal which required a further assessment prior to the extraction.

摘要

背景/目的:下颌第三磨牙(MTM)术前影像学检查对于预防下牙槽神经(IAN)损伤至关重要。本研究旨在评估全景X线片(PAN)上被视为IAN损伤风险增加指标的征象,并将其与锥形束CT(CBCT)结果相关联。

材料与方法

选取2012年1月至2018年1月期间拔除MTM的58例患者。对全景X线片评估以下征象:根管顶中断、牙根变黑、牙根偏斜与变窄、根管偏移、MTM牙根与下颌管重叠。在CBCT图像上评估根管皮质丧失、牙根沟、舌侧皮质变薄与穿孔。采用卡方检验和多因素逻辑回归检验来检验PAN征象与CBCT结果之间的关系。

结果

共检查了79颗MTM。22例(27.8%)病例在CBCT上可见根管皮质丧失。PAN图像上牙根变黑是最常见的影像学征象。PAN上的根管偏移和白线中断与CBCT图像上MTM与下颌管之间的根管皮质丧失具有统计学显著相关性(分别为p = 0.004和p = 0.012)。其他PAN征象与CBCT结果未观察到统计学显著关联。

结论

根管偏移和白线中断与CBCT上的根管皮质丧失相关,表明牙根与下颌管直接接触,拔牙前需要进一步评估。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验